QuickScan™ I QD24XX General Purpose Handheld Area Imager Bar Code Reader Product Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 ©2013 Datalogic ADC, Inc. An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
Table of Contents INTRODUCTION ................................................................................................................................................................................ 1 About this Manual .......................................................................................................................................................................................... 1 Overview ......................................................................................
Contents USB Keyboard Speed .....................................................................................................................................................................................................41 USB Keyboard Numeric Keypad ................................................................................................................................................................................42 USB-OEM Interface ..........................................................
Contents UPC-E ............................................................................................................................................................................................ 86 UPC-E Enable/Disable ....................................................................................................................................................................................................86 UPC-E Check Character Transmission ..................................................
Contents GS1-128 ......................................................................................................................................................................................119 GS1-128 Enable ............................................................................................................................................................................................................. 119 GS1-128 2D Component ...............................................................
Contents GS1 DataBar™ Omnidirectional GS1-128 Emulation ....................................................................................................................................... 151 GS1 DataBar™ Omnidirectional 2D Component .............................................................................................................................................. 152 GS1 DATABAR™ EXPANDED .........................................................................................................
Contents PDF417 ........................................................................................................................................................................................................188 PDF417 Enable / Disable ................................................................................................................................................................................................................. 188 PDF417 Length Control ................................
Contents STANDARD DEFAULTS ................................................................................................................................................................ 245 SAMPLE BAR CODES.................................................................................................................................................................... 255 KEYPAD ................................................................................................................................
Contents NOTES 8 QuickScan™ I QD24XX
Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.
Technical Support Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: Notes contain information necessary for properly diagnosing, repairing and operating the reader. The CAUTION symbol advises you of actions that could damage equipment or property.
About the Reader About the Reader The QuickScan™ QD2400 2D Imager was specifically created to address the needs of retailers and meet the market demand with outstanding omni-directional reading performance on virtually all codes at an affordable price. Elegant design details are incorporated into a smaller, balanced lightweight enclosure without sacrificing Datalogic’s well-known durability.
Programming the Reader Programming the Reader Configuration Methods Programming Bar Codes The reader is factory-configured with a standard set of default features. After scanning the interface bar code, you can select other options and customize your reader through use of the instructions and programming bar code labels available in the corresponding features section for your interface. Customizable settings for many features are found in "Configuration Parameters" starting on page 15.
Chapter 2 Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 2. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container. Setting Up the Reader ollow the steps provided in this section to connect and get your reader up and communicating with its host. 1.
Setup Installing the Interface Cable onnect the reader cable by inserting the cable into the handle as shown in Figure 1. To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 1. Connect/disconnect the cable RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 2.
Installing the Interface Cable Keyboard Wedge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 3. Figure 3. Keyboard Wedge Interface connection USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 4. Figure 4.
Setup nd Figure 5. Other Interface Connections Wa Ke M or... IB W ybo ed ard ge or... Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the reader remain the same.
Interface Selection Setting the Interface Scan the programming bar code from this section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding section in this manual (also listed in Table 1 on page 9) to configure any desired settings and features associated with that interface. Unlike some programming features and options, interface selections require that you scan only one programming bar code label.
Setup KEYBOARD FEATURES $P,HA2B,P(CR) USB Keyboard with alternate key encoding Select USB Alternate Keyboard $P,HA29,P(CR) AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT $P,HA11,P(CR) Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK $P,HA26,P(CR) AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Set KEYBOARD WEDGE Interface Features Select KBD-AT-ALT $P,HA10,P(CR) Keyboard Wedge
Interface Selection KEYBOARD (continued) Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard FEATURES $P,HA15,P(CR) Select KBD-IBM-M $P,HA16,P(CR) Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx $P,HA1B,P(CR) Select KBD-DIG-VT Set KEYBOARD WEDGE Interface Features starting on page 33 $P,HA35,P(CR) USB Keyboard with standard key encoding Select USB Keyboard $P,HA2C,P(CR)
Setup Customizing Configuration Settings Configure Interface Settings If after scanning the interface bar code from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type in "Configuration Parameters" starting on page 15.
Customizing Configuration Settings Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration bar code below. This will restore the custom configuration for the currently active interface. Custom defaults are based on the interface type.
Setup NOTES 14 QuickScan™ I QD24XX
Chapter 3 Configuration Using Bar Codes This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional methods of programming, see "Configuration Methods" on page 4. You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 5 and complete the appropriate procedure.
Enter/Exit Programming Mode 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING bar code to exit Programming Mode.
Enter/Exit Programming Mode GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels.
Enter/Exit Programming Mode NOTES 18 QuickScan™ I QD24XX
RS-232 INTERFACE BAUD RATE on page 20 DATA BITS on page 21 STOP BITS on page 21 PARITY on page 22 HANDSHAKING CONTROL on page 23 Use the programming bar codes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in the next section, "RS-232/USB-Com Interfaces" starting on page 24.
Enter/Exit Programming Mode Baud Rate See page 206 for information on this feature.
Enter/Exit Programming Mode Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. $CR2DA00(CR) 7 Data Bits $CR2DA01(CR) DEFAULT 8 Data Bits Stop Bits Set the number of stop bits to match host device requirements. See page 206 for more information on this feature.
Enter/Exit Programming Mode Parity This feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 206 for more information.
Enter/Exit Programming Mode Handshaking Control See page 206 for more information about this feature.
RS-232/USB-COM INTERFACES INTERCHARACTER DELAY on page 25 BEEP ON ASCII BEL on page 25 BEEP ON NOT ON FILE on page 26 ACK NAK OPTIONS on page 27 ACK CHARACTER on page 28 NAK CHARACTER on page 28 ACK NAK TIMEOUT VALUE on page 29 ACK NAK RETRY COUNT on page 29 ACK NAK ERROR HANDLING on page 30 INDICATE TRANSMISSION FAILURE on page 30 DISABLE CHARACTER on page 31 ENABLE CHARACTER on page 31 The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
Enter/Exit Programming Mode Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 215 for more information.
Enter/Exit Programming Mode Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
Enter/Exit Programming Mode ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 208 for more information.
Enter/Exit Programming Mode ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 208 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
Enter/Exit Programming Mode ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 210 for more information on setting this feature.
Enter/Exit Programming Mode ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Enter/Exit Programming Mode Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. See page 212 for more information on setting this feature.
Enter/Exit Programming Mode NOTES 32 QuickScan™ I QD24XX
KEYBOARD SETTINGS COUNTRY MODE on page 34 SEND CONTROL CHARACTERS on page 38 WEDGE QUIET INTERVAL on page 39 INTERCODE DELAY on page 39 CAPS LOCK STATE on page 40 NUMLOCK on page 40 USB KEYBOARD SPEED on page 41 USB KEYBOARD NUMERIC KEYPAD on page 42 Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Enter/Exit Programming Mode Country Mode This feature specifies the country/language supported by the keyboard. Several languages are supported: $CKBCO00(CR) DEFAULT Country Mode = U.S. $CKBCO01(CR) Country Mode = Belgium $CKBCO02(CR) Country Mode = Britain $CKBCO11(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia $CKBCO0E(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO04(CR) Country Mode = France $CKBCO13(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = French Canadian $CKBCO05(CR) Country Mode = Germany $CKBCO0D(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Hungary $CKBCO06(CR) Country Mode = Italy $CKBCO0C(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO14(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Lithuanian $CKBCO07(CR) Country Mode = Norway $CKBCO12(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Poland $CKBCO08(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Country Mode (continued) $CKBCO09(CR) Country Mode = Spain $KBCO0A(CR) Country Mode = Sweden $CKBCO0B(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode Send Control Characters This feature specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Enter/Exit Programming Mode Wedge Quiet Interval Specifies amount of time to look for keyboard activity before scanner breaks keyboard connection in order to transmit data to host. The selectable range for this setting is 00 to 990 milliseconds (00-0x63 by 01) in increments of ten milliseconds. See page 214 in “References” for detailed information and examples for setting this feature.
Enter/Exit Programming Mode Caps Lock State This option specifies the format in which the reader sends character data. This does not apply when an alternate key encoding keyboard is selected. $CKBCL00(CR) DEFAULT Caps Lock State = Caps Lock OFF $CKBCL01(CR) Caps Lock State = Caps Lock ON $CKBCL02(CR) Caps Lock State = AUTO Caps Lock Enable Numlock This option specifies the setting of the NUMLOCK key in the Keyboard Wedge interface.
Enter/Exit Programming Mode USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface.
Enter/Exit Programming Mode USB Keyboard Speed (continued) $CKBSP07(CR) USB Keyboard Speed = 7ms $CKBSP08(CR) USB Keyboard Speed = 8ms $CKBSP09(CR) USB Keyboard Speed = 9ms $CKBSP0A(CR) USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
USB-OEM INTERFACE USB-OEM DEVICE USAGE on page 44 USB INTERFACE OPTIONS on page 44 Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USB-OEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix B for a listing of standard factory settings.
Enter/Exit Programming Mode USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
Enter/Exit Programming Mode Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: IBM Standard Format: Send labels in standard IBM format.
Enter/Exit Programming Mode Interface Options This feature provides for an interface-specific control mechanism.
DATA FORMAT GLOBAL PREFIX/SUFFIX starting on page 48 GLOBAL AIM ID starting on page 49 LABEL ID starting on page 52 • • • • • Label ID: Pre-Loaded Sets Individually Set Label ID Label ID Control Label ID Symbology Selection • 1D Symbologies Label ID Symbology Selection • 2D Symbologies CASE CONVERSION starting on page 59 CHARACTER CONVERSION starting on page 60 It is not recommended to use these features with IBM interfaces.
Enter/Exit Programming Mode Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the bar code data, also called a header) and/or as a suffix (in a position following the bar code data, also called a footer). See page 219 for more detailed instructions on setting this feature.
Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See Table 2 on page 3-49 for a listing of AIM IDs. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see some samples in the table below), followed by...
Enter/Exit Programming Mode DATABAR EXPANDED COMPOSITE DATABAR LIMITED DATABAR LIMITED COMPOSITE DATA MATRIX EAN128 EAN128 COMPOSITE EAN13 EAN13 P2 EAN13 P5 EAN13 COMPOSITE EAN8 EAN8 P2 EAN8 P5 EAN8 COMPOSITE FOLLET 2OF5 I2OF5 IATA INDUSTRIAL 2OF5 INDUSTRIAL 2OF5 ISBN ISBT128 CONCAT ISSN MAXICODE MICRO QR MICRO PDF MSI PDF417 PLESSEY POSTAL AUSTRALIAN POSTAL IMB POSTAL JAPANESE POSTAL KIX POSTAL PLANET POSTAL PORTUGAL POSTAL POSTNET BB POSTAL ROYAL MAIL POSTAL SWEDISH POSTNET QR CODE S25 TRIOPTIC UPCA UPCA
Enter/Exit Programming Mode Set AIM ID Individually for GS1-128 This feature configures a Label ID individually for the GS1-128 symbology and the programming for this works the same way as Label ID. See Label ID: Set Individually Per Symbology, starting on page 224 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Label ID A Label ID is a customizable code of up to three ASCII characters (convert to Hex using the ASCII Chart on the inside back cover of this manual), used to identify a bar code symbology type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs or individually per symbology (see "Individually Set Label ID" on page 53).
Enter/Exit Programming Mode Individually Set Label ID This feature configures a Label ID individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to Label ID Symbology Selection • 1D Symbologies, starting on page 54 to select the symbology you want to set, followed by up to 3 characters from the ASCII Chart at the back of this manual.
Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 52 or page 224 in “References” for more detailed instructions. If less than the expected string of 3 characters are selected, scan the ENTER/EXIT bar code twice to accept the selection and exit Programming Mode.
Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CCCID Set Code 39 CIP Label ID Character(s) $C8BID Set EAN 8 Label ID Character(s) $C8MID Set EAN 8 Composite Label ID Character(s) $C82ID Set EAN 8 P2 Label ID Character(s) $C85ID Set EAN 8 P5 Label ID Character(s) $CF2ID Set Follett 2 of 5 Label ID Character(s) $C4BID Set GS1 DataBar 14 Label ID Character(s) $C4CID Set GS1 DataBar 14 Composite Label ID Character(s) Product Reference Guide $C35ID Set EAN 13
Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CXBID Set GS1 DataBar Expanded Label ID Character(s) $CIAID Set IATA Industrial 2 of 5 Label ID Character(s) $CPMID Set IMB Postal Code Label ID Character(s) $CU2ID Set Industrial 2 of 5 Label ID Character(s) $CI2ID Set Interleaved 2 of 5 Label ID Character(s) $CISID Set ISBN Label ID Character(s) $CINID Set ISSN Label ID Character(s) $CPJID Set Japan Postal Code Label ID Character(s) 56 $CGBID Set GTIN 8 Lab
Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CPZID Set PZN Code Label ID Character(s) $CPRID Set Royal Postal Code Label ID Character(s) $CS2ID Set Standard 2 of 5 Label ID Character(s) $CPSID Set Swedish Postal Code Label ID Character(s) $CCTID Set Trioptic Code Label ID Character(s) $CAMID Set UPC-A Composite Label ID Character(s) $CA2ID Set UPC-A P2 Label ID Character(s) $CA5ID Set UPC-A P5 Label ID Character(s) $CEBID Set UPC-E Label ID Character(s) $
Enter/Exit Programming Mode Label ID Symbology Selection − 2D Symbologies $CAZID Set Aztec Label ID Character(s) $CCSID Set China Sensible Label ID Character(s) $CDMID Set Data Matrix Label ID Character(s) $CMQID Set Micro QR Label ID Character(s) 58 $CMXID Set Maxicode Label ID Character(s) $CP4ID Set PDF 417 Label ID Character(s) $CMIID Set Micro PDF 417 Label ID Character(s) $CQRID Set QR Code Label ID Character(s) QuickScan™ I QD24XX
Enter/Exit Programming Mode Advanced Formatting: User Label Edit Advanced formatting is available to create user label edit scripts. See the Datalogic Aladdin configuration application or contact Technical Support. Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.
Enter/Exit Programming Mode Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
READING PARAMETERS DOUBLE READ TIMEOUT starting on page 62 LED AND BEEPER INDICATORS starting on page 64 • • • • • • • Power On Alert Good Read: When to Indicate Good Read Beep Type Good Read Beep Frequency Good Read Beep Length Good Read Beep Volume Good Read LED Duration SCANNING FEATURES starting on page 69 • • • • • • • • • • • • • • • • • Scan Mode Stand Mode Indication Stand Operation Pick Mode Stand Mode Sensitivity Stand Mode Illumination Off Time Scanning Active Time Stand Illumination Control F
Enter/Exit Programming Mode Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read. $CSNDR0A(CR) Double Read Timeout = 0.1 Second $CSNDR14(CR) Double Read Timeout = 0.
Enter/Exit Programming Mode Double Read Timeout (continued) $CSNDR50(CR) Double Read Timeout = 0.8 Second $CSNDR5A(CR) Double Read Timeout = 0.
Enter/Exit Programming Mode LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. $CBPPU00(CR) Power On Alert = Disable (No Audible Indication) $CBPPU01(CR) DEFAULT Power On Alert = Power-up Beep Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code.
Enter/Exit Programming Mode Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. $CBPTY00(CR) DEFAULT Good Read Beep Type = Mono $CBPTY01(CR) Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.
Enter/Exit Programming Mode Good Read Beep Length $CBPLE06(CR) Good Read Beep Length = 60 msec $CBPLE08(CR) DEFAULT Good Read Beep Length = 80 msec $CBPLE0A(CR) Good Read Beep Length = 100 msec $CBPLE0C(CR) Good Read Beep Length = 120 msec $CBPLE0E(CR) Good Read Beep Length = 140 msec $CBPLE10(CR) Good Read Beep Length = 160 msec $CBPLE12(CR) Good Read Beep Length = 180 msec $CBPLE14(CR) Good Read Beep Length = 200 msec 66 QuickScan™ I QD24XX
Enter/Exit Programming Mode Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
Enter/Exit Programming Mode Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps the LED on until the next trigger pull. See page 227 in “References” for detailed instructions and examples for setting this feature.
Enter/Exit Programming Mode SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 228 in “References” for descriptions. $CSNRM00(CR) DEFAULT Scan Mode = Trigger Single $CSNRM01(CR) Scan Mode = Trigger Hold Multiple $CSNRM02(CR) Scan Mode = Trigger Pulse Multiple $CSN- Scan Mode = Flashing $CSNRM04(CR) Scan Mode = Always On $CSN- Scan Mode = Stand Mode Options concerning Stand Mode behavior are available at the following feature, Stand Operation.
Enter/Exit Programming Mode Stand Mode Indication This operation is useful for indicating when the reader is in Stand Mode. If enabled, the blue indicator will blink when Stand Mode scanning is active. If the reader is removed from its Stand support or from the Base Station (cordless models) and switches out of Stand Mode into Triggered Mode, blinking will stop until Stand Mode is active again.
Enter/Exit Programming Mode Stand Operation Specifies the behavior of the reader when stationary in a stand. There are two conditions which cause the reader to switch to Stand Mode: 1. The reader is manually configured to switch to Stand Mode or when inserted into the special Stand support which automatically enables the Stand Mode. 2. The reader is placed into the cradle of the base station (cordless models only). Below are further options concerning Stand Operation. Ignore Autorecognition.
Enter/Exit Programming Mode Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet. This feature is not compatible with Multiple Labels Reading in a Volume. $CSNPM00(CR) DEFAULT Pick Mode = Disable $CSNPM01(CR) Pick Mode = Enable Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup.
Enter/Exit Programming Mode Stand Mode Illumination Off Time Specifies the amount of time reader illumination stays off after pulling the trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). See page 229 in “References” for a description of this feature.
Enter/Exit Programming Mode Stand Illumination Control Controls the illumination status while the reading mode is stand mode and the reader is attempting to detect objects. $CSMIL00(CR) DEFAULT Stand Illumination Control = OFF $CSMIL01(CR) Stand Illumination Control = ON $CSMIL02(CR) Stand Illumination Control = Dim Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.
Enter/Exit Programming Mode Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 233 in “References” for detailed information on setting this feature.
Enter/Exit Programming Mode Aiming Duration Timer Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode.The range for this setting is from 1 to 255 seconds in 1-second increments. See page 231 in “References” for a description of this feature. LSTM00 DEFAULT Aiming Off After Decoding LSTM Set Aiming Duration Timer Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Enter/Exit Programming Mode Green Spot Duration Specifies the duration of the good read pointer beam after a good read. $CLSSP00(CR) Green Spot Duration = Disable (Green Spot is Off ) $CLSSP01(CR) DEFAULT Green Spot Duration = Short (300 msec) $CLSSP02(CR) Green Spot Duration = Medium (500 msec) $CLSSP03(CR) Green Spot Duration = Long (800 msec) Mobile Phone Mode This mode is useful for scanning bar codes displayed on a mobile phone.
Enter/Exit Programming Mode Partial Label Reading Control Enable/Disable to ignore partial labels to be read within the boundary of the field of view. IPPL00 Partial Label Reading Control = Disable IPPL01 Partial Label Reading Control = Enable Decode Negative Image Enable/Disable the ability to decode a negative image for all symbologies. When this feature is enabled, you will be unable to read normally-printed labels or programming labels in this manual.
Enter/Exit Programming Mode MULTIPLE LABEL READING In standard (default) mode, when the reader’s aiming system is activated (by a trigger pull, motion or other method depending on the mode), it then acquires and processes each image in the area in front of it (the Volume). In this case, the scanner stops processing the image once it decodes a label. If several labels are present in the volume, only the first label encountered is decoded and sent.
Enter/Exit Programming Mode Multiple Labels Ordering by Code Symbology This feature allows you to specify the order multiple labels are transmitted by symbology type, when Multiple Labels per Frame is enabled. See page 234 in “References” for detailed information on setting this feature.
1D SYMBOLOGIES 1D Code Selection The reader supports the following 1D symbologies (bar code types). See "2D Symbologies" starting on page 173 for 2D bar codes. Symbology-dependent options are included in each chapter.
Enter/Exit Programming Mode DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING Mode bar code. 2. Scan the Disable All Symbologies bar code. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING bar code. $AD(CR) Disable All Symbologies This does not disable the reading of programming labels.
Enter/Exit Programming Mode CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.
Enter/Exit Programming Mode UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A bar codes. $CABEN00(CR) UPC-A = Disable $CABEN01(CR) DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A bar code data.
Enter/Exit Programming Mode Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CAB3B00(CR) DEFAULT UPC-A to EAN-13 = Don’t Expand $CAB3B01(CR) UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
Enter/Exit Programming Mode UPC-A 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CAB2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $CAB2D01(CR) EAN-13 2D Component = 2D component must be decoded UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E bar codes.
Enter/Exit Programming Mode UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E bar code data. $CEBCT00(CR) UPC-E Check Character Transmission = Don’t Send $CEBCT01(CR) DEFAULT UPC-E Check Character Transmission = Send UPC-E 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Enter/Exit Programming Mode Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CEB3B00(CR) DEFAULT UPC-E to EAN-13 = Don’t Expand $CEB3B01(CR) UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
Enter/Exit Programming Mode UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. $CEBNS00(CR) UPC-E Number System Character = Do not transmit $CEBNS01(CR) DEFAULT UPC-E Number System Character = Transmit GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14character format.
Enter/Exit Programming Mode EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 bar codes. $C3BEN00(CR) EAN 13 = Disable $C3BEN01(CR) DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 bar code data.
Enter/Exit Programming Mode EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. $C3BF100(CR) EAN-13 Flag 1 Char= Don’t transmit $C3BF101(CR) DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
Enter/Exit Programming Mode EAN-13 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $C3B2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $C3B2D01(CR) EAN-13 2D Component = 2D component must be decoded ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
Enter/Exit Programming Mode EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 bar codes. $C8BEN00(CR) EAN 8 = Disable $C8BEN01(CR) DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar code data.
Enter/Exit Programming Mode Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. $C8B3B00(CR) DEFAULT Expand EAN 8 to EAN 13 = Disable $C8B3B01(CR) Expand EAN 8 to EAN 13 = Enable EAN 8 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Enter/Exit Programming Mode UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits.
Enter/Exit Programming Mode UPC/EAN Quiet Zones This feature specifies the number of quiet zones for UPC/EAN labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label. The property applies to all EANUPC symbologies globally and to the ADDONs.
Enter/Exit Programming Mode ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
Enter/Exit Programming Mode Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 101.
Enter/Exit Programming Mode Optional Add-On Timer (continued) $CADOT06(CR) Optional Add-on Timer = 60ms $CADOT07(CR) DEFAULT Optional Add-on Timer = 70ms $CADOT0A(CR) Optional Add-on Timer = 100ms $CADOT0C(CR) Optional Add-on Timer = 120ms $CADOT0E(CR) Optional Add-on Timer = 140ms $CADOT10(CR) Optional Add-on Timer = 160ms Product Reference Guide 99
Enter/Exit Programming Mode Optional Add-On Timer (continued) $CADOT12(CR) Optional Add-on Timer = 180ms $CADOT14(CR) Optional Add-on Timer = 200ms $CADOT16(CR) Optional Add-on Timer = 220ms $CADOT18(CR) Optional Add-on Timer = 240ms $CADOT1A(CR) Optional Add-on Timer = 260ms $CADOT1C(CR) Optional Add-on Timer = 280ms $CADOT1E(CR) Optional Add-on Timer = 300ms 100 QuickScan™ I QD24XX
Enter/Exit Programming Mode Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 98.
Enter/Exit Programming Mode Optional GS1-128 Add-On Timer (continued) $CADUT06(CR) Optional GS1-128 Add-On Timer = 60ms $CADUT07(CR) Optional GS1-128 Add-On Timer = 70ms $CADUT0A(CR) Optional GS1-128 Add-On Timer = 100ms $CADUT0C(CR) Optional GS1-128 Add-On Timer = 120ms $CADUT0E(CR) Optional GS1-128 Add-On Timer = 140ms $CADUT10(CR) Optional GS1-128 Add-On Timer = 160ms 102 QuickScan™ I QD24XX
Enter/Exit Programming Mode Optional GS1-128 Add-On Timer (continued) $CADUT12(CR) Optional GS1-128 Add-On Timer = 180ms $CADUT14(CR) Optional GS1-128 Add-On Timer = 200ms $CADUT16(CR) Optional GS1-128 Add-On Timer = 220ms $CADUT18(CR) Optional GS1-128 Add-On Timer = 240ms $CADUT1A(CR) Optional GS1-128 Add-On Timer = 260ms $CADUT1C(CR) Optional GS1-128 Add-On Timer = 280ms $CADUT1E(CR) Optional GS1-128 Add-On Timer = 300ms Product Reference Guide 103
Enter/Exit Programming Mode CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable $CC3EN00(CR) Code 39 = Disable $CC3EN01(CR) DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
Enter/Exit Programming Mode Code 39 Check Character Calculation (continued) $CC3CC04(CR) Code 39 Check Character Calculation = Enable Italian Post Check $CC3CC08(CR) Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 bar code data.
Enter/Exit Programming Mode Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. $CC3SS00(CR) DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit $CC3SS01(CR) Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
Enter/Exit Programming Mode Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label.
Enter/Exit Programming Mode Code 39 Set Length 1 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 0 to 50 characters. Table 3 provides examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 3.
Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 4 provides examples for setting Length 2. See page 217 for detailed instructions on setting this feature. Table 4.
Enter/Exit Programming Mode TRIOPTIC CODE The following options apply to the Trioptic symbology. Trioptic Code Enable/Disable $CCTEN00(CR) DEFAULT Trioptic Code = Disable $CCTEN01(CR) Trioptic Code = Enable CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 bar codes.
Enter/Exit Programming Mode Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Quiet Zones" on page 107 "Code 39 Length Control" on page 107 "Trioptic Code" on page 110 Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 bar code data.
Enter/Exit Programming Mode CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. $CCCEN00(CR) DEFAULT Code 39 CIP = Disable $CCCEN01(CR) Code 39 CIP = Enable CODE 39 DANISH PPT The following options apply to the Code 39 Danish PPT symbology. Code 39 Danish PPT Enable/Disable Enables/Disables AIM ID for Code 39 Danish PPT Codes.
Enter/Exit Programming Mode CODE 39 LAPOSTE The following options apply to the Code 39 LaPoste symbology. Code 39 LaPoste Enable/Disable Enables/disables the ability of the scanner to decode Code39 La Poste labels. $CLPEN00(CR) DEFAULT Code 39 LaPoste = Disable $CLPEN01(CR) Code 39 LaPoste = Enable CODE 39 PZN The following options apply to the Code 39 PZN symbology. Code 39 PZN Enable/Disable Enables/disables the ability of the scanner to decode Code39 PZN labels.
Enter/Exit Programming Mode CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 bar codes. $CC8EN00(CR) Code 128 = Disable $CC8EN01(CR) DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Enter/Exit Programming Mode Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 bar code data. $CC8CT00(CR) DEFAULT Code 128 Check Character Transmission = Don’t Send $CC8CT01(CR) Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Enter/Exit Programming Mode Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
Enter/Exit Programming Mode Code 128 Set Length 1 Specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 80 characters. Table 5 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 5.
Enter/Exit Programming Mode Code 128 Set Length 2 This feature specifies one of the bar code lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 6 provides examples for setting Length 2.
Enter/Exit Programming Mode GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels.
Enter/Exit Programming Mode CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. $CI8CE00(CR) DEFAULT ISBN 128 Concatenation = Disable $CI8CE01(CR) ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled.
Enter/Exit Programming Mode ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see "ISBT 128 Concate- nation" on page 120).
Enter/Exit Programming Mode ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
Enter/Exit Programming Mode ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation, use the Datalogic Aladdin configuration application or contact Datalogic Technical Support, as described on page 2. INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 bar codes.
Enter/Exit Programming Mode I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. Combinations of these settings are possible via the Aladdin configuration utility, or contact Technical Support.
Enter/Exit Programming Mode I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 bar code data. $CI2CT00(CR) I 2 of 5 Check Character Transmission = Don’t Send $CI2CT01(CR) DEFAULT I 2 of 5 Check Character Transmission = Send I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode I 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 7 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 7.
Enter/Exit Programming Mode I 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 8 provides examples for setting Length 2.
Enter/Exit Programming Mode INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. $CCHEN00(CR) DEFAULT Interleaved 2 of 5 CIP HR = Disable $CCHEN01(CR) Interleaved 2 of 5 CIP HR = Enable FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology.
Enter/Exit Programming Mode STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 bar codes. $CS2EN00(CR) DEFAULT Standard 2 of 5 = Disable $CS2EN01(CR) Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
Enter/Exit Programming Mode Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. $CS2CT00(CR) Standard 2 of 5 Check Character Transmission = Don’t Send $CS2CT01(CR) DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
Enter/Exit Programming Mode Standard 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 1 to 50 characters. Table 9 provides some examples for setting Length 1. See page 217 if you want detailed instructions on setting this feature. Table 9.
Enter/Exit Programming Mode Standard 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 10 provides examples for setting Length 2.
Enter/Exit Programming Mode INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. $CU2EN00(CR) DEFAULT Industrial 2 of 5 = Disable $CU2EN01(CR) Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Enter/Exit Programming Mode Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. $CU2CT00(CR) Industrial 2 of 5 Check Character Transmission = Disable $CU2CT01(CR) DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
Enter/Exit Programming Mode Industrial 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 0 to 50 characters. Table 11 provides some examples for setting Length 1. See page 217 if you want detailed instructions on setting this feature. Table 11.
Enter/Exit Programming Mode Industrial 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. $CIAEN00(CR) DEFAULT IATA = Disable $CIAEN01(CR) IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Enter/Exit Programming Mode CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar bar codes. $CCBEN00(CR) DEFAULT Codabar = Disable $CCBEN01(CR) Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
Enter/Exit Programming Mode Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar bar code data. $CCBCT00(CR) Codabar Check Character Transmission = Don’t Send $CCBCT01(CR) DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
Enter/Exit Programming Mode Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. $CCBSC00(CR) Codabar Check Character Set = ABCD/TN*E $CCBSC01(CR) Codabar Check Character Set = ABCD/ABCD $CCBSC02(CR) Codabar Check Character Set = abcd/tn*e $CCBSC03(CR) DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match.
Enter/Exit Programming Mode Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label. $CCBLO02(CR) Codabar Quiet Zones = Quiet Zones on two sides $CCBLO03(CR) DEFAULT Codabar Quiet Zones = Small Quiet Zones on two sides Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology.
Enter/Exit Programming Mode Codabar Set Length 1 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Table 13 provides some examples for setting Length 1.
Enter/Exit Programming Mode Codabar Set Length 2 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters.
Enter/Exit Programming Mode ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. $CCBAB00(CR) DEFAULT ABC Codabar = Disable $CCBAB01(CR) ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
Enter/Exit Programming Mode ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
Enter/Exit Programming Mode ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
Enter/Exit Programming Mode CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 bar codes. $CC1EN00(CR) DEFAULT Code 11 = Disable $CC1EN01(CR) Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
Enter/Exit Programming Mode Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. $CC1CT00(CR) Code 11 Check Character Transmission = Don’t Send $CC1CT01(CR) DEFAULT Code 11 Check Character Transmission = Send Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode Code 11 Set Length 1 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. Table 15 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 15.
Enter/Exit Programming Mode Code 11 Set Length 2 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 16 provides examples for setting Length 2.
Enter/Exit Programming Mode GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional bar codes.
Enter/Exit Programming Mode GS1 DataBar™ Omnidirectional 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded. $C4B2D00(CR) DEFAULT GS1 DataBar™ Omnidirectional 2D Component = Disable (2D component not required) $C4B2D01(CR) GS1 DataBar™ Omnidirectional 2D Component = 2D component must be decoded GS1 DATABAR™ EXPANDED The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology.
Enter/Exit Programming Mode GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded bar codes will be translated to the GS1-128 label data format. $CXBU800(CR) DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable $CXBU801(CR) GS1 DataBar™ Expanded GS1-128 Emulation = Enable GS1 DataBar™ Expanded 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
Enter/Exit Programming Mode GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length: For variable-length decoding, a minimum length may be set. Fixed Length: For fixed-length decoding, two different lengths may be set.
Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters. Table 17 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 17.
Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 18 provides examples for setting Length 2.
Enter/Exit Programming Mode GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited bar codes. $CLBEN00(CR) DEFAULT GS1 DataBar™ Limited = Disable $CLBEN01(CR) GS1 DataBar™ Limited = Enable GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited bar codes will be translated to the GS1-128 label data format.
Enter/Exit Programming Mode GS1 DataBar™ Limited 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CLB2D00(CR) DEFAULT GS1 DataBar™ Limited 2D Component = Disable (2D component not required) $CLB2D01(CR) GS1 DataBar™ Limited 2D Component = 2D component must be decoded CODE 93 The following options apply to the Code 93 symbology.
Enter/Exit Programming Mode Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.
Enter/Exit Programming Mode Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Code 93 Set Length 1 Specifies one of the bar code lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 19 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 19.
Enter/Exit Programming Mode Code 93 Set Length 2 This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode Code 93 Quiet Zones Enables/disables quiet zones for Code 93. $CC9LO02(CR) Code 93 Quiet Zones = Quiet Zones on two sides $CC9LO03(CR) DEFAULT Code 93 Quiet Zones = Small Quiet Zones on two sides MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
Enter/Exit Programming Mode MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. $CMSCC00(CR) MSI Check Character Calculation = Disable $CMSCC01(CR) DEFAULT MSI Check Character Calculation = Enable Mod10 $CMSCC02(CR) MSI Check Character Calculation = Enable Mod11/10 $CMSCC03(CR) MSI Check Character Calculation = Enable Mod10/10 MSI Check Character Transmission Enables/disables transmission of an MSI check character.
Enter/Exit Programming Mode MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode MSI Set Length 1 This feature specifies one of the bar code lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 21 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 21.
Enter/Exit Programming Mode MSI Set Length 2 This feature specifies one of the bar code lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. $CPLEN00CR) DEFAULT Plessey = Disable $CPLEN01CR) Plessey = Enable Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character. $CPLCC00(CR) Plessey Check Character Calculation = Disable $CPLCC01(CR) DEFAULT Plessey Check Character Calculation = Enable Plessey std.
Enter/Exit Programming Mode Plessey Check Character Transmission Enables/disables transmission of an MSI check character. $CPLCT00(CR) Plessey Check Character Transmission = Disable $CPLCT01(CR) DEFAULT Plessey Check Character Transmission = Enable Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode Plessey Set Length 1 This feature specifies one of the bar code lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 23 provides some examples for setting Length 1. See page 217 for detailed instructions on setting this feature. Table 23.
Enter/Exit Programming Mode Plessey Set Length 2 This feature specifies one of the bar code lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode NOTES 172 QuickScan™ I QD24XX
2D SYMBOLOGIES 2D Global Features • • 2D Maximum Decoding Time on page 174 2D Structured Append on page 175 • 2D Normal/Inverse Symbol Control on page 175 The reader supports the following 2D symbologies (bar code types). Symbology-dependent options for each symbology are included in this chapter. See "1D Code Selection" starting on page 81 for configuration of 1D bar codes.
Enter/Exit Programming Mode 2D Maximum Decoding Time This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
Enter/Exit Programming Mode 2D Structured Append Enables/disables ability of reader to append multiple 2D Codes labels in a structured format. The structured append property is globally applied to the following symbologies, if these are enabled: • • Data Matrix QR Code • • Aztec PDF 417 $CDESA00(CR) DEFAULT Structured Append = Disable $CDESA01(CR) Structured Append = Enable 2D Normal/Inverse Symbol Control Specifies the options available for decoding normal/negative printed 2D symbols.
Enter/Exit Programming Mode Aztec Code Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. $CAZEN00(CR) DEFAULT Aztec Code = Disable $CAZEN01(CR) Aztec Code = Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Aztec Code Set Length 1 Specifies one of the bar code lengths for Aztec Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Aztec Code Set Length 2 This feature specifies one of the bar code lengths for Aztec Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode China Sensible Code China Sensible Code Enable / Disable Enables/disables the ability of the reader to decode China Sensible Code labels. $CCSEN00(CR) DEFAULT China Sensible Code = Disable $CCSEN01(CR) China Sensible Code = Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode China Sensible Code Set Length 1 Specifies one of the bar code lengths for China Sensible Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode China Sensible Code Set Length 2 This feature specifies one of the bar code lengths for China Sensible Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Data Matrix Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. $CDMEN00(CR) Data Matrix = Disable $CDMEN01(CR) DEFAULT Data Matrix = Enable Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors.
Enter/Exit Programming Mode Data Matrix Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Data Matrix Set Length 2 This feature specifies one of the bar code lengths for Data Matrix Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Maxicode Maxicode Enable / Disable Enables/disables ability of reader to decode Maxicode labels. $CMXEN00(CR) DEFAULT Maxicode = Disable $CMXEN01(CR) Maxicode = Enable Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable.
Enter/Exit Programming Mode Maxicode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Maxicode Set Length 2 This feature specifies one of the bar code lengths for Maxicode Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode PDF417 PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels. $CP4EN00(CR) PDF417 = Disable $CP4EN01(CR) DEFAULT PDF417 = Enable PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode PDF417 Set Length 1 Specifies one of the bar code lengths for PDF417 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710. See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode PDF417 Set Length 2 This feature specifies one of the bar code lengths for PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Characters can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01.
Enter/Exit Programming Mode Micro PDF417 Micro PDF417 Enable / Disable Enables/disables the ability of the reader to decode Micro PDF417 labels. $CMIEN00(CR) DEFAULT Micro PDF417 = Disable $CMIEN01(CR) Micro PDF417 = Enable Micro PDF417 Code 128 GS1-128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1-128 emulation.
Enter/Exit Programming Mode Micro PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Micro PDF417 Set Length 2 This feature specifies one of the bar code lengths for Micro PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the bar code’s data characters only. Characters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered to be 0366. See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode QR Code QR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels. $CQREN00(CR) QR Code = Disable $CQREN01(CR) DEFAULT QR Code = Enable QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode QR Code Set Length 1 Specifies one of the bar code lengths for QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode QR Code Set Length 2 This feature specifies one of the bar code lengths for QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Micro QR Code Micro QR Code Enable/Disable Enables/disables the ability of the reader to decode Micro QR Code labels. MQEN00 DEFAULT Micro QR Code = Disable MQEN01 Micro QR Code = Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Micro QR Code Set Length 1 Specifies one of the bar code lengths for Micro QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Micro QR Code Set Length 2 This feature specifies one of the bar code lengths for Micro QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 217 for detailed instructions on setting this feature.
Enter/Exit Programming Mode UCC Composite UCC Composite Enable / Disable Enables/disables the ability of the reader to decode the stacked part of a UCC Composite label. This feature is not effective when Global AIM IDs are enabled (see "Global AIM ID" on page 49).
UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on.
Postal Code Selection Enables/disables the ability of the scanner to decode labels of a specific postal symbology.
Postal Code Selection (continued) $CPOEN06(CR) Postal Code Selection = Enable Japan Post $CPOEN07(CR) Postal Code Selection = Enable IMB $CPOEN08(CR) Postal Code Selection = Enable Sweden Post $CPOEN09(CR) Postal Code Selection = Enable Portugal Post Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels.
NOTES 204 QuickScan™ I QD24XX
Chapter 4 References This section contains explanations and examples of selected bar code features. See Configuration Using Bar Codes, starting on page 15 for the actual bar code labels used to configure the reader.
References RS-232 Parameters RS-232 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly. Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream.
RS-232 Parameters RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits.
References ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
RS-232 Parameters NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: 1. Determine the desired character or value. 2.
References ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits.
RS-232 Parameters ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
References Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set the value: 1. Determine the desired character or value.
RS-232 Parameters Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: Determine the desired character or value.
References Keyboard Interface Wedge Quiet Interval Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits.
Keyboard Interface Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments).
References Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Go to page 39 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode. 4. Scan the bar code: SELECT INTERCODE DELAY SETTING. 5.
Symbologies Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. Set Length 1 This feature specifies one of the bar code lengths for Length Control.
References 4. Scan the appropriate two digits from the keypad in Appendix D, Keypad that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. 5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode. This completes the procedure.
Data Editing Please Keep In Mind... • • • • Modifying a message string is not a mandatory requirement. Data editing is a sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE. A prefix or suffix may be applied only to a specified symbology (reference 1D Code Selection, starting on page 81) or across all symbologies (set via the Global features in this chapter).
References Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent).
Data Editing Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" below) or individually per symbology (see "Label ID: Set Individually Per Symbology" on page 224).
References USA Label ID set Symbology EU Label ID set Default Character Default ASCII Default Character Default ASCII DATABAR 14 R4 523400 u 750000 DATABAR 14 COMPOSITE R4 523400 c 523400 DATABAR EXPANDED RX 525800 t 740000 DATABAR EXPANDED COMPOSITE RX 525800 d 525800 DATABAR LIMITED RL 524C00 v 760000 DATABAR LIMITED COMPOSITE RL 524C00 i 524C00 DATA MATRIX Dm 446D00 w 770000 EAN128 000000 k 6B0000 EAN128 COMPOSITE 000000 $E 244500 EAN13 F 460000 B 4200
Data Editing USA Label ID set Symbology MATRIX 2OF5 Default Character EU Label ID set Default ASCII Default Character Default ASCII g MAXICODE MC 4D4300 x 780000 MICRO QR $Q 245100 $Q 245100 MICRO PDF mP 6D5000 8 380000 MSI @ 400000 Z 5A0000 PDF417 P 500000 r 720000 PLESSEY a 610000 a 610000 POSTAL AUSTRALIAN $K 244B00 $K 244B00 POSTAL IMB $V 245600 $V 245600 POSTAL JAPANESE $R 245200 $R 245200 POSTAL KIX $U 245500 $U 245500 POSTAL PLANET $W 245700
References Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to page 53 and scan the ENTER/EXIT bar code. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate bar code in the section "Label ID Control" on page 53. Reference Figure 9 for Label ID positioning options if multiple identification features are enabled. 3.
Data Editing Table 36. Label ID Examples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT bar code (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix data using Label ID Control, starting on page 53 Enable as Suffix Enable as Prefix Enable as Suffix 3.
References Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
Reading Parameters Reading Parameters Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2.
References Scanning Features Scan Mode This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader.
Scanning Features Stand Mode Off Time This feature specifies the amount of time reader illumination stays off after pulling the trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 = 20, etc. 3.
References Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 73 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode. 4.
Scanning Features Aiming Duration Time Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 76 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode. 4.
References Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
Scanning Features Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
References Multiple Labels Ordering by Code Symbology This feature Specifies the transmission ordering by symbology type, when Multiple Labels per Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string to 12 characters if not using all six symbologies. The labels are ordered first as specified in the output mask. Labels present in the volume but not specified will be transmitted as unspecified symbologies in random order as allowed by the reading time sequence.
Scanning Features Table 44.
References 236 QuickScan™ I QD24XX
Appendix A Technical Specifications Table 45 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 45. Technical Specifications . Item Description QD24XX Physical Characteristics Color Dimensions Weight (without cable) Black & White Height 6.4"/163 mm Length 3.6"/91 mm Width 1.6"/41 mm Approximately 5.1 ounces/145 g Electrical Characteristics Input Voltage: 4.5 - 14.
Technical Specifications Item Description Depth of Field (Typical) a Symbology QD24XX 5mil: 0.2" - 5.9" (0.5 - 15cm) Code 39 10mil: 0" - 8.7" (0 - 22cm) 20mil: up to 16" (40cm) EAN 7.5mil: 0" - 5.9" (0 - 15cm) 13mil: 0.2" - 13.8" (0.5 - 35cm) 6.6mil: 0.39" - 5.1" (1.0 - 130cm) PDF 417 10mil: 0" - 8.3" (0 - 21cm) 15mil: 0.2" - 9.5" (0.5 - 24cm) Data Matrix QR Code 10mil: 0.39" - 5.1" (1.0 - 13 cm) 15mil: 0" - 7.1" (0 - 18cm) 10mil: 0.2" - 5.1" (0.5 - 13cm) 15mil: 0" - 7.
Technical Specifications Item Description 1D Bar Codes UPC/EAN/JAN (A, E, 13, 8); UPC/EAN/JAN (including P2 /P5); UPC/EAN/JAN (including; ISBN /Bookland & ISSN); UPC/EAN Coupons; Code 39 (including full ASCII); Code 39 Trioptic; Code39 CIP (French Pharmaceutical); LOGMARS (Code 39 w/ standard check digit enabled); Danish PPT; Code 32 (Italian Pharmacode 39); Code 128; Code 128 ISBT; Interleaved 2 of 5; Standard 2 of 5; Interleaved 2 of 5 CIP (HR); Industrial 2 of 5; Discrete 2 of 5; IATA 2of5 Air cargo co
Technical Specifications Item Description User Environment Operating Temperature 0° to 50° C (32° to 122° F) Storage Temperature -40° to 70 °C (-40° to 158° F) Humidity Drop Specifications Ambient Light Immunity Contaminants Spray/ Rain/Dust/Particulates Operating: 0% to 95% relative humidity, non-condensing Scanner withstands 18 drops from 1.5 meters (5.0 feet) to concrete Up to 86,000 Lux IEC 529-IP42 ESD Level 16 KV Regulatory Electrical Safety UL 60950, CSA C22.2 No.
Technical Specifications Imager Labeling Sample labels are shown here to illustrate their location only. Please view the labels on your product for actual details, as they may vary from those depicted. Scanner Regulatory Label The QuickScan™ Handheld Reader is not user-serviceable. Opening the case of the unit can cause internal damage and will void the warranty.
Technical Specifications Standard Cable Pinouts Figure 10 and Table 46 provide standard pinout information for the interface cable. Figure 10. Standard Cable Pinouts: Handheld Bottom of Scanner Pin 10 Cable Strain Relief To Host Pin 1 Cable Clip (Latch) Interface Cable Port Cable The signal descriptions in Table 46 apply to the connector on the reader and are for reference only. Table 46.
Technical Specifications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels. Table 47.
Technical Specifications Table 48. Programming Mode Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. LED blinks continuously Reader sounds four low frequency beeps. A label has been rejected. N/A Reader sounds three times at lowest frequency & current volume.
Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 49.
Standard Defaults Parameter Default Your Setting Page Number KEYBOARD WEDGE Country Mode U.S.
Standard Defaults Parameter Good Read LED Duration Default Your Setting Page Number 300 ms 68 Trigger Single 69 Disable 70 Switch to Stand Mode 71 Pick Mode Disable 72 Stand Mode Sensitivity Medium 72 Stand Mode Illumination Off Time 2 Seconds 73 Scanning Active Time 5 Seconds 73 OFF 74 Flash On Time 10 = Flash is ON for 1 Second 74 Flash Off Time 06 = Flash is OFF for 600ms 75 Aiming Pointer Enable 75 Aiming Off After Decoding 76 Green Spot Duration 300 ms 77 Mobile
Standard Defaults Parameter Expand UPC-A to EAN-13 Default Your Setting Page Number Don’t Expand 85 Transmit 85 2D Component Not Required 86 Enable 86 Send 87 2D Component Not Required 87 Expand UPC-E to EAN-13 Don’t Expand 88 Expand UPC-E to UPC-A Don’t Expand 88 Transmit 89 Disable 89 Enable 90 Send 90 EAN-13 Flag 1 Character Transmit 91 EAN-13 ISBN Conversion Disable 91 EAN-13 2D Component 2D Component Not Required 92 Disable 92 Enable 93 Send 93 Disable 94
Standard Defaults Parameter Default Your Setting Page Number Add-Ons Disable P2, P5 and P8 97 70 ms 98 Disable 101 Code 39 Enable/Disable Enable 104 Code 39 Check Character Calculation Disable 104 Send 105 Don’t Transmit 106 Disable 106 Small Quiet Zones on two sides 107 Variable 107 Code 39 Set Length 1 2 108 Code 39 Set Length 2 50 109 Disable 110 Disable 110 Don’t Send 111 Don’t Transmit 111 Disable 112 Code 39 Danish PPT Enable/Disable Disable 112 Code 39 LaP
Standard Defaults Parameter Code 128 Function Character Transmission Default Your Setting Page Number Don’t Send 115 Small Quiet Zones on two sides 116 Variable 116 Code 128 Set Length 1 1 117 Code 128 Set Length 2 80 118 Transmit in Code 128 Data Format 119 Disable 119 ISBT 128 Concatenation Disable 120 ISBT 128 Force Concatenation Disable 120 ISBT 128 Concatenation Mode Static 121 200 msec 122 I 2 of 5 Enable/Disable Disable 123 I 2 of 5 Check Character Calculation Disab
Standard Defaults Parameter Default Your Setting Page Number Standard 2 of 5 Set Length 1 8 131 Standard 2 of 5 Set Length 2 50 132 Industrial 2 of 5 Enable/Disable Disable 133 Industrial 2 of 5 Check Character Calculation Disable 133 Industrial 2 of 5 Check Character Transmission Enable 134 Industrial 2 of 5 Length Control Variable 134 Industrial 2 of 5 Set Length 1 1 135 Industrial 2 of 5 Set Length 2 50 136 IATA Enable/Disable Disable 137 IATA Check Character Transmission
Standard Defaults Parameter Code 11 Enable/Disable Default Your Setting Page Number Disable 147 Check C and K 147 Send 148 Variable 148 Code 11 Set Length 1 4 149 Code 11 Set Length 2 50 150 GS1 DataBar™ Omnidirectional Enable/Disable Disable 151 GS1 DataBar™ Omnidirectional GS1-128 Emulation Disable 151 2D component not required 152 GS1 DataBar™ Expanded Enable/Disable Disable 152 GS1 DataBar™ Expanded GS1-128 Emulation Disable 153 GS1 DataBar™ Expanded 2D Component 2D comp
Standard Defaults Parameter Default Your Setting Page Number Small Quiet Zones on two sides 163 Disable 163 Enable Mod10 164 MSI Check Character Transmission Enable 164 MSI Length Control Variable 166 MSI Set Length 1 1 166 MSI Set Length 2 50 167 Disable 168 Enable Plessey std. check char.
Standard Defaults Parameter Data Matrix Length Control Default Your Setting Page Number Variable 183 Data Matrix Set Length 1 1 183 Data Matrix Set Length 2 3,116 184 Maxicode Enable / Disable Disable 185 Maxicode Primary Message Transmission Disable 185 Maxicode Length Control Variable 186 Maxicode Set Length 1 1 186 Maxicode Set Length 2 0145 187 PDF417 Enable / Disable Enable 188 PDF417 Length Control Variable 188 PDF417 Set Length 1 1 189 PDF417 Set Length 2 2,710 1
Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types.
Sample Bar Codes Sample Bar Codes (continued) Code 32 Codabar 13579 Code 93 Code 11 123456789 256 QuickScan™ I QD24XX
Sample Bar Codes GS1 DataBar™ (RSS) GS1 DataBar™ variants must be enabled to read the bar codes below (see GS1 DataBar™ Omnidirectional on page 151).
Sample Bar Codes 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode PDF 417 Micro PDF 417 ABCabc BV17453 QR Code Micro QR Code 123456 35900G9 UCC Composite 258 QuickScan™ I QD24XX
Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.
Keypad 260 A B C D E F QuickScan™ I QD24XX
Appendix E Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms. Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE Table 50.
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE (continued) Table 51. Scancode Set When Control Character is 02 0x x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab Home F6 F1 F2 F3 F4 F5 xB xC Enter S+ Tab Keypd xF Enter Ins Pg Up Pg Dwn 2x Space ! “ # $ % & ‘ ( ) * + , - .
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode Table 52.
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued) Table 53.
Digital Interface Table 54.
IBM31xx 102-key Table 56.
IBM XT Table 58. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS C(S)+H CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - .
Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
NOTES 270 QuickScan™ I QD24XX
ASCII Chart ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP ! “ # $ % & ’ ( ) * + , .
www.datalogic.com ©2013 Datalogic ADC, Inc. All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Datalogic ADC, Inc.