QuickScanTM QS6500BT General Purpose Handheld Linear Imager Bar Code Reader with Bluetooth® Wireless Technology Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Datalogic Scanning, Inc. QUICKSCANTM END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product’s operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
3. Transfers, Support. 3.1 3.2 3.3 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic transfer, or other use of the Software on other than the designated Datalogic Product will be a material breach of this Agreement. However, Datalogic may elect not to terminate this Agreement or the granted licenses, but instead may elect to notify End User that End User is deemed to have ordered and accepted a license for each breaching use.
7. Infringement. 7.1 7.2 7.3 7.
ware, End User agrees to sign a waiver prepared by Datalogic concerning further use of the embedded Software. End User’s resumed or continued use of the embedded Software after termination shall constitute End User’s agreement to be bound by the terms and conditions of this Agreement for such use. 11. General Provisions. 11.1 11.2 11.3 11.4 11.5 Entire Agreement; Amendment.
NOTES Quick Reference Guide v
NOTES vi QuickScanTM QS6500BT
Installation The QuickScanTM QS6500BT linear imager is easy to install and use. The following figures show the steps to perform an installation. Turn off the host computer before connection. Consult the host terminal’s manual if necessary. 1 2 I/F 8 Base Station Cable Routing 3 Power 9 5 4 7 6 1. Lift the cable retainer. 2. Connect the interface (I/F) cable to the Base Station. For Power Off Terminal application with standard USB interface, attach to USB 1.0, 1.1 or 2.0 host device ONLY. NOTE 3.
8. Place the linear imager in the Base Station and verify the charge LED is flashing. After five minutes, the scanner will have sufficient charge to begin reading labels. A full charge from depleted battery will take approximately 2 hours. 9. Press and hold the link button on the bottom of the Base Station for three seconds. This will ensure that any other imager link to the Base Station will be broken.
Battery Warnings and Cautions WARNING Do not discharge the battery using any device except for the linear imager. When the battery is used in devices other than the linear imager, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury. Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions.
Always charge the battery at 32°–113°F (0°–45°C) temperature range. CAUTION Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the linear imager and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Power Supply Models require either a Listed class II or class III with a Limited Power Source (LPS). For the safety certification to be valid, class III input power sources must be IEC/EN60950-1 (EN 60335series, EN 60065 or relevant) approved. Input: 100 - 240 VAC Output: 9 - 12 VDC Max. Current: 2.5 A Max. Power: 30 W For USB Power Off Terminal applications, attach to USB 1.0, 1.1 or 2.0 host device ONLY. NOTE LED and Beeper Indications Some LED and Beeper indications are user-configurable.
How to Scan The figure below shows the right and wrong ways to scan a bar code. 1 1 PDF 2 2 1. The linear imager must be pointed at a slight angle to the bar code so that the light reflected off the bar code can be “seen” by the linear imager. Do not hold the linear imager perpendicular to the bar code. 2. The targeting beam must cross the entire label. The linear imager cannot read the bar code data without seeing the entire label.
Troubleshooting If the linear imager is not operating properly, the following checks should be performed: 1. The BT linear imager uses an internal battery and if the battery is fully depleted or failed, the linear imager will not operate. Exchange the battery with a known good unit and retest the linear imager. uct Prod ence r Refe ide Gu 4 1 2 3 5 2. Verify the interface cable is securely attached to the host.
6. Verify that the Base Station power cable is securely attached and the external power adapter is plugged in. If the linear imager still does not function properly, contact your local supplier or Datalogic Customer Support Services. Statement of Compliance This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference; and 2.
• Connect the equipment into an outlet on a circuit different from that to which receiver is connected • Consult the dealer or an experienced radio I TV technician for help. FCC Caution statement "The User is cautioned that changes or modifications not expresely approved by the part responsible for compliance could void the user's authorify to operate the equipment.
NOTES 10 QuickScanTM QS6500BT
EC DECLARATION OF CONFORMITY Datalogic hereby declares that the apparatus specified below and as referenced in the EC Type Approval Certificate has been tested and found compliant to the following European Council Directives and harmonized Standards. Equipment Type: Handheld Barcode Scanning Equipment Apparatus: QuickscanTM QS6500BT with Base Station Manufactured by: Placed into EU Service: Datalogic Scanning, Inc. 959 Terry St.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.