290 QuickScan
TM
Lite QW2100
LED and Beeper Indications
INDICATION DESCRIPTION LED BEEPER
Power-up Beep
The reader is in the process of
powering-up.
Reader beeps four times at high-
est frequency and volume upon
power-up.
Good Read Beep
A label has been successfully
scanned by the reader.
LED behavior for this indi-
cation is configurable via
the feature “
Good Read:
When to Indicate
The reader will beep once at cur-
rent frequency, volume, mono/bi-
tonal setting and duration upon a
successful label scan.
ROM Failure
There is an error in the reader's
software/programming
Flashes
Reader sounds one error beep
at highest volume.
Limited Scanning
Label Read
Indicates that a host connection
is not established when the USB
interface is enabled.
N/A
Reader 'chirps' six times at the
highest frequency and current
volume.
Reader Active
Mode
The reader is active and ready to
scan.
The LED is lit steadily
a
a.
Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
N/A
Reader
Disabled
The reader has been disabled by
the host.
The LED blinks continu-
ously
N/A
Green Spot is on
continuously
While in Stand Mode or Trigger
Object Sense mode the green
spot shall be on while in stand
watch state.
N/A N/A
Green Spot
a
flashes momen-
tarily
Upon successful read of a label,
the software shall turn the green
spot on for the time specified by
the configured value.
N/A N/A
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode Entry
A valid programming label has
been scanned.
LED blinks continuously
Reader sounds four low fre-
quency beeps.
Label Program-
ming Mode
Rejection of Label
A label has been rejected. N/A
Reader sounds three times at
lowest frequency & current vol-
ume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where multiple labels
must be scanned to program one
feature, this indication acknowl-
edges each portion as it is suc-
cessfully scanned.
N/A
Reader sounds one short beep
at highest frequency & current
volume.
Label Program-
ming Mode
Acceptance of
Programming
Configuration option(s) have
been successfully programmed
via labels and the reader has
exited Programming Mode.
N/A
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by reset
beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned. N/A
Reader sounds two times at low