Touch TD1100 General Purpose Corded Handheld Contact Imager Bar Code Reader Quick Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
Table of Contents Software Product Policy ............................................................................................... iv Customers Under Software Support .............................................................. iv Parts of the Reader .......................................................................................................... 1 Holder/Hands-Free Stand ............................................................................................ 2 Setup ..................
Datalogic ADC, Inc. TOUCHTM PRODUCT SERIES END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
.2 End User shall not disclose, provide, or otherwise make available the Proprietary Information of Datalogic or its third party licensors to any person other than End User's authorized employees or agents who are under confidentiality agreement, and End User shall not use the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for End User's internal business purposes.
Software Product Policy 10.1Either party may terminate this Agreement or any license granted under this Agreement at any time upon written notice if the other party breaches any provision of this Agreement. 10.
Touch TD1100 Quick Reference Guide The Touch™ TD1100 series of linear imaging contact readers represent the Datalogic ADC solution for customers who require a cost-effective solution for close contact bar code reading without sacrificing quality and performance. Designed for low throughput applications within multiple markets, the Touch TD1100 readers provide the guarantee of contact reading with an excellent reading performance on virtually all linear bar codes, including damaged or poorly printed codes.
Holder/Hands-Free Stand Holder/Hands-Free Stand The TD1100 Holder can be used as a hands-free stand. Refer to Scanning Modes on page 9 for information about programming the reader for use with the stand. Figure 1.
Setup Connect Host Interface Keyboard Wedge Interface Key bo ard 23 2 RS-232 Interface RS - B USB Interface US Quick Reference Guide 3
Setup Touch and Scan 65° 65° 4 Touch TD1100
Programming Bar Codes Programming Bar Codes For your convenience, this guide includes the programming bar codes required to configure the reader for use with different interface (terminal/host) types. See the Product Reference Guide (PRG) for more complete information about programming and configurable features. You can download the latest version of the PRG and any other available publications for the reader from the website listed on the back cover of this manual.
Programming Bar Codes RS-232 Interface To use an RS-232 interface, scan the bar code for the desired RS-232 host type.
Programming Bar Codes USB Interface The reader attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. When using a USB interface, the reader auto-detects the USB and defaults to the USB Keyboard interface. Select USB-COM-STD1 (simulates RS-232 standard interface) Select USB Keyboard (with standard key encoding) Select USB Alternate Keyboard (with alternate key encoding) Select USB OEM 1. Download the appropriate USB Com driver from www.
Programming Bar Codes Keyboard Wedge Interface To use a Keyboard Wedge interface, scan the bar code for the desired keyboard type. Select KBD-AT (AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding) Select KBD-AT-NK (IBM AT PS2 with standard key encoding but without external kbd.
Scanning Modes Wand Emulation Interface To use a Wand Emulation interface, scan the bar code below. Select WAND Scanning Modes If the interface type is changed, scanner configuration may automatically reset to a different Scanning Mode.
Scanning Modes Scanning Modes (continued) Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Hands-Free Mode 10 Touch TD1100
Troubleshooting Troubleshooting Problem Possible Cause No power to the reader. Nothing happens when the trigger is pulled. Interface or power cables are loose. Possible Solutions Check system power. Ensure power supply is connected. Ensure all cable connections are secure. Ensure reader is programmed to read Reader not programmed for cor- the type of bar code scanned. Refer to rect bar code type. the Product Reference Guide (PRG) for more information.
Technical Features Technical Features Item Description Physical Characteristics Color Dimensions Weight Black; Other colors and custom logo options are available for minimum quantity purchase. Touch 65: 16.0 x 8.4 x 5.8 cm / 6.3 x 3.3 x 2.3 in Touch 90: 17.0 x 10.4 x 6.7 cm / 6.7 x 4.1 x 2.7 in Touch 65: 130.0 g / 4.6 oz Touch 90: 153.0 g / 5.4 oz Electrical Characteristics Current Operating (Typical): < 100 mA @ 5 VDC Standby/Idle (Typical): 20 mA @ 5 VDC Max 180mA @ 5VDC Input Voltage 5 VDC +/- 0.
Technical Features Item Description Decoding Capability Humidity Autodiscriminates all standard 1D codes including GS1 DataBar™ linear codes. GS1 DataBar Expanded Stacked; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional 5 - 95% Drop specifications Withstands repeated drops from 1.5 m / 5.
LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. A “Green Spot” also lights to indicate a good read. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming bar code labels.
Regulatory Information Regulatory Information All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment. Power Supply Use only a power supply approved by Datalogic for this product and model.
Regulatory Information Reader Labeling The label is shown here to illustrate its location only. Please view the labels on your product for actual details. Datalogic ADC Limited Factory Warranty Warranty Coverage Datalogic warrants to Customer that Datalogic's products will be free from defects in materials and workmanship for a period of 5 years from product shipment. This warranty does not extend to batteries and cables.
Regulatory Information duration published by Datalogic for the product at the time of purchase (Warranty period). Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period, whichever is longer.
Services and Support No Assignment Customer may not assign or otherwise transfer its rights or obligations under this warranty except to a purchaser or transferee of product. No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic.
Services and Support NOTES Quick Reference Guide 19
Services and Support NOTES 20 Touch TD1100
DECLARATION OF CONFORMITY EC-79 Rev.: 0 Pag.: 1 di 1 Datalogic ADC, Inc. 959 Terry St.
www.datalogic.com Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 © 2012-2013 Datalogic ADC, Inc. 820049914 (Rev.