User's Manual

Installation & Operation Manual V 1.0 10 (19)
Use:
The rising edge of IN1 starts reading
The rising edge of IN2 stops reading
t
1
min 100 us
t
2
min 100 ms
See Appendix B to know where IN±1 pins are.
See Appendix B for electric characteristics of the input.
*bu Not available
*rd Restore default settings
*kw Not available
*rm[_] Reader request rate:
*rm0 Reader mode SLOW* (1 out of 256)
*rm1 Reader mode FAST (default) (1out of4)
*mt[_] Modulation type:
*mt0 modulation type ASK*
*mt1 modulation type FSK (default)
*tm[_] Tag response rate:
*tm0 tag mode SLOW*
*tm1 tag mode FAST (default)
*mi[_] Modulation index:
*mi0 modulation index 10%
*mi1 modulation index 30% (default)
*mi2 modulation index 100%
*sa[_] Stand alone mode:
*sa0 stand alone mode disabled (default)
*sa1 stand alone mode enabled (detect)
*sa2 stand alone mode enabled (totalize)
When stand alone mode is enabled the device will start reading as
soon as it turned on.
*br[_] baud rate:
*br0 baud rate 9600
*br1 baud rate 19200
*br2 baud rate 38400
*br3 baud rate 57600
*br4 baud rate 115200 (default)
*tt[_] Tag technology:
*tt1 tag technology ISO 15693(T-BT1320 T-BT1315) (default)
*tt2 tag technology Philips I-Code I (not available).
*tt4 tag technology TI Tag It (not available).
*ts[_] Time slots:
*ts0 time slots single
*ts1 16 times slots (default)
*xm[_] Rx mode:
*xm0 mode Rx/Tx (one antenna connected to channels 1 to 6) (default)
*xm1 mode Rx and Tx separate (two antennas : one connected to
channels 1 to 6 and the other connected to RX channel).
*cl[_] Code length:
See Appendix A for more details.
*cl0 16 characters UIDs (standard, default)
*cl1 10 characters UIDs (base conversion) not implemented
*cl2 12 characters UIDs (partial code)
*cl3 12 characters UIDs (First character special)
*an[_] HF antenna select:
Selects the channel to which the antenna is connected (if the reader is
Multichannel).
*an0 select HF antenna 1 (default)
*an1 select HF antenna 2