*ec[_] Echo:
*ec0 echo disabled (default)
*ec1 echo enabled
“echo” makes it possible to view the characters sent to the reader.
*sa[_] Stand alone mode:
*sa0 stand alone mode disabled (default)
*sa1 stand alone mode enabled (detect)
When stand alone mode is enabled, the device will start reading
as soon as it is turned on.
*nl[_] New Line character(s) selection:
*nl0 line feed and carriage return (0x0D 0x0A) (default)
*nl1 line feed (0x0A)
*nl2 carriage return (0x0D)
*nl3 carriage return and line feed(0x0A 0x0D)
*pw[_] Output power:
*pw[0 .. 4000] range of power from 0 to 4000 mW (default 2000
mW)
- Example *pw2000
The selected output power is an approximate value.
*dt[_] Time between UIDs:
This parameter inserts a time delay between the transmission of
codes.
*dt[0..200] range of time between UIDs from 0 to 200 units
(default 0), 1 unit = 10 ms (example: *dt10 >> 100ms)
*lc[_] Lock code:
*lc0 lock code disabled (default)
*lc1 lock code 1 enabled
*lc2 lock code 2 enabled
Details for *lc1:
Any transponder is read just once.
To read a transponder again, another one must be read first.
The transponder is first detected only once without regard to the time spent in the field.
*ti[_] Time out:
*ti[0 .. 180] time parameter for lock code 2 from 0 [s] to 180 [s]
(default 10 [s], example *ti10)
*sk[_] Skip time slot on no response:
*sk0 skip on no response off
*sk1 skip on no response on (default)
*ct[_] Collision threshold parameter:
*ct[0 .. 100] parameter from 0 to 100 (default 33, example *ct33)
*et [_] Communication selection :
*et0 ethernet
*et1 RS232
*et2 RS232 and ethernet (default)
*br[_] baud rate:
*br0 baud rate 9600
*br1 baud rate 19200
*br2 baud rate 38400
*br3 baud rate 57600
*br4 baud rate 115200 (default)
*cl[_] Code length:
See Appendix A for more details.