User's Manual

Table Of Contents
9.4.13 Gets the current time
Command syntax: “?TM” [CR]
Command answer: [CR][LF] ”TM=14.58.45” [CR][LF]
Command action: Gets the current time
Parameter range: none
Description: this command retrieves the current time.
9.4.14 Clears the memory’s data
Command syntax: “.rX” [CR]
Command answer: [LF]
Command action: Clears the memory’s data
Parameter range: none.
Description: this command clears the memory’s data.
9.4.15 Downloads the memory’s data
Command syntax: “.rF” [CR]
Command answer: [CR][LF] ” D004815B5E” [CR][LF]
[CR][LF] ” D0048A1B5E” [CR][LF]
[CR][LF] ” D00481C51” [CR][LF] …
Command action: downloads the memory’s data
Parameter range: none.
Description: this command downloads the memory’s data. If no data is stored in the memory, then the
answer is: [LF] [BEL].
9.4.16 Clears the message area
Command syntax: “.m0” [CR]
Command answer: [LF]
Command action: clears the message area
Parameter range: none.
Description: this command clears the message area on the display.
9.4.17 Write a message to the display
Command syntax: “.m#” [**max 15 char**][CR]
Command answer: [LF]
Command action: writes a message to the display at the row #
Parameter range: #= 1 to 3.
Description: this command writes a message to the display at the row #. The message string has to be
a maximum of 15 characters. The message can be written on row 1, 2 or 3 on the display.
R-PO7470 Manual – v. 1.1 – August 2008 27