User's Manual
Table Of Contents
- Contents:
- 1 Description
- 2 Operation
- 3 Managing the menu
- 4 Connect your R-PO7470 to a PC
- 5 Battery managment
- 6 Take care of your reader
- 7 Specifications
- 8 Regulations
- 9 Technical supplement – Console commands
- 9.1 Introduction
- 9.2 How to connect the R-PO7470 to a PC through USB
- 9.3 How to connect the R-PO7470 to a PC through BlueTooth
- 9.4 Console commands description
- 9.4.1 Get firmware version command
- 9.4.2 Read remotely command
- 9.4.3 Sets the date’s year
- 9.4.4 Sets the date’s month
- 9.4.5 Sets the date’s day of the month
- 9.4.6 Sets the date’s day of the week
- 9.4.7 Sets the current date format
- 9.4.8 Gets the current date format
- 9.4.9 Gets the current date
- 9.4.10 Sets the time’s hour
- 9.4.11 Sets the time’s minute
- 9.4.12 Sets the time’s second
- 9.4.13 Gets the current time
- 9.4.14 Clears the memory’s data
- 9.4.15 Downloads the memory’s data
- 9.4.16 Clears the message area
- 9.4.17 Write a message to the display
- 9.4.18 Sets the “store in memory” function
- 9.4.19 Gets the “store in memory” function status
- 9.4.20 Sets the “memory hit” function
- 9.4.21 Gets the “memory hit” function
- 9.4.22 Sets the “selected hit” function
- 9.4.23 Gets the “selected hit” function
- 9.4.24 Sets the “reading beep” function
- 9.4.25 Gets the “reading beep” function status
- 9.4.26 Sets the “key beep” function
- 9.4.27 Gets the “key beep” function status
- 9.4.28 Sets the reading timeout
- 9.4.29 Gets the reading timeout
- 9.4.30 Sets the shutdown timeout
- 9.4.31 Gets the shutdown timeout
- 9.4.32 Sets the VCP baud rate
- 9.4.33 Gets the VCP baud rate
- 9.4.34 Sets the “auto shutdown” function
- 9.4.35 Gets the “auto shutdown” function status
- 9.4.36 Firmware update function
- 9.4.37 Character length function
9.4.13 Gets the current time
• Command syntax: “?TM” [CR]
• Command answer: [CR][LF] ”TM=14.58.45” [CR][LF]
• Command action: Gets the current time
• Parameter range: none
Description: this command retrieves the current time.
9.4.14 Clears the memory’s data
• Command syntax: “.rX” [CR]
• Command answer: [LF]
• Command action: Clears the memory’s data
• Parameter range: none.
Description: this command clears the memory’s data.
9.4.15 Downloads the memory’s data
• Command syntax: “.rF” [CR]
• Command answer: [CR][LF] ” D004815B5E” [CR][LF]
[CR][LF] ” D0048A1B5E” [CR][LF]
[CR][LF] ” D00481C51” [CR][LF] …
• Command action: downloads the memory’s data
• Parameter range: none.
Description: this command downloads the memory’s data. If no data is stored in the memory, then the
answer is: [LF] [BEL].
9.4.16 Clears the message area
• Command syntax: “.m0” [CR]
• Command answer: [LF]
• Command action: clears the message area
• Parameter range: none.
Description: this command clears the message area on the display.
9.4.17 Write a message to the display
• Command syntax: “.m#” [**max 15 char**][CR]
• Command answer: [LF]
• Command action: writes a message to the display at the row #
• Parameter range: #= 1 to 3.
Description: this command writes a message to the display at the row #. The message string has to be
a maximum of 15 characters. The message can be written on row 1, 2 or 3 on the display.
R-PO7470 Manual – v. 1.1 – August 2008 27