Inaccurate Undercounting FIREFLY
Gas FIREFLY:
Ensure the drive shaft is engaged properly and turns freely.
Look at index speed; excessive index speed can cause under-counting. Continually undercounting
deltas usually means the account has an undersized meter, making both the meter and FIREFLY
miss counts.
Electric FIREFLY:
Check connection of FIREFLY to power posts. Reconnect using the proper technique if needed.
Confirm there are no reflective unpainted areas within the painted area of the disc.
Check meter disc speed; excessive disc spend can cause under-counting. Continually undercounting
deltas usually means the account has an undersized meter, making both the meter and FIREFLY
miss counts.
Tightening Gas FIREFLY onto register
Do not over-tighten screws on the Gas FIREFLY.
Breakage due to negligence may not be covered under warranty.