Operator`s manual
120  A-Class 
Electrical 
Input Voltage:  90 – 132 / 180 – 264 VAC @ 47 – 63 Hz, auto-ranging 
Grounding:  Unit must be connected to a properly grounded circuit. 
Power Consumption:  A-4xxx models:  90 watts, typical operating / 10 watts, standby 
   A-6xxx models:  120 watts, typical operating / 10 watts, standby 
Environmental 
Operating Temperature: 
40° F – 100° F (4°C – 38° C) 
Storage Temperature: 
-40°F – 150°F (-40° C – 60° C) 
Relative Operating Humidity: 
10% – 90% (non-condensing) 
Relative Storage Humidity: 
5% – 95% (non-condensing) 
Electromagnetic Radiation:  Moderate RF fields can be tolerated. 
Dust: 
Non-conducting, non-corrosive 
Fonts (See Appendix B for examples.) 
Resident:  Nine alphanumeric fonts from .035 inch (.89 mm) to 16 inches (40.5 
cm) and OCR-A and OCR-B; CG Triumvirate™ from AFGA® in 
both Portrait and Landscape orientations (from 6 to 72 point). 
Scalable: 
CG Triumvirate™ and CG Triumvirate Bold Condensed™, also 
downloaded True Type formats. 
Expansion:  All fonts expandable vertically up to 24x. 
Rotation: 
Fonts (and graphics) can be printed in four directions: 0°, 90°, 180°, 
270°. 
Character Set:  66 Selectable Code Pages (PC_850 Multilingual set by default) 
 Note:  CG Triumvirate and CG Triumvirate Bold Condensed Scaleable Fonts do not support the Unicode code 
page. 