Operator`s manual
A-Class  145 
WARNING 
Failure to properly configure the jumper settings of the GPIO Port may result in damage to the printer and / or the applicator. 
GPIO Port (J2) Pin Functions and Associated Jumper Selections 
Pin 
# 
Signal 
Name 
Signal 
Direction 
Active 
Setting 
Jumper 
Placement 
Function / 
Description 
 Ground  Ground  JMP 7 ‘On’   Printer chassis ground is used 
1 
Ground (Configurable) 
Open  Open  JMP 7 ‘Off’  Ground Return must be supplied 
Output  +5 VDC  JMP 8 ‘On’  Printer +5 VDC is used (.5 amp max.) 
2 
+5 VDC (Configurable) 
Open  Open  JMP 8 ‘Off’  +5 VDC must be supplied 
3 Start Of Print 
 [5]
 Input Programmable 
[1]
4 Slew Label 
[4]
 Input  Low 
5 Pause Toggle   Input  Low 
6 Reprint 
[3] 
 Input  Low 
7  +24 VDC (1.0 amp max.)  Output  +24 VDC 
8 Ground   Ground Ground 
N/A 
N/A 
9  Ribbon Low  Output  Programmable 
[1]
10 Service Required 
[2]
 Output  Low 
11  End Of Print  Output  Programmable 
[1]
12  Media Out  Output  Low 
13  Ribbon Out  Output  Low 
14  Data Ready (DRDY)  Output  Low 
JMP 9: 
 Pins 1 & 2 = +5 VDC
– OR – 
Pins 2 & 3 = +24 VDC
See WARNING message, above. 
When inactive, all output pins will be pulled up to the voltage 
determined by this jumper setting. 
15 Spare 
 Output N/A  N/A  N/A 
[1] 
For details see Section 4.2.4. 
[2]
 Evoked by occurrences listed under ‘Fault Messages’ in Section 6.2.
[3]
 Reprints the last label exactly, with no increment or time stamp changes; use it for error conditions. Always keeping this signal LOW will result in non-stop printing.
[4]
 Advances media until the signal goes HIGH and, if not in continuous mode, the media will be positioned at the next available media TOF. 
[5]
 If active with no current print job, “WAITING FOR DATA” is displayed. Specifying a quantity of 9999 while always keeping this signal ‘ON’ will cause non-stop label 
printing, except in single label mode (see Imaging Mode, Section 4.2.5), which will cause the printer to stop between labels; see Timing Diagrams, below.  