Operator`s manual
A-Class  65 
Communications (continued) 
Displayed Menu Item  Details 
HEAT COMMAND 
Allows the user to disable the DPL Heat Command, providing 
compatibility with other DATAMAX printers. 
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL Heat command is ignored. The heat value is controlled via the 
menu setting; see Section 4.2.3. 
SPEED COMMANDS 
Allows the user to disable the DPL speed commands (Print, Feed, 
Slew, and Reverse). 
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL speed commands are ignored. The speeds are controlled via 
the menu setting; see Section 4.2.3. 
TOF SENSING COMMANDS 
Allows the user to disable the DPL Top of Form commands (Gap, 
Continuous, and Reflective). 
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL TOF commands are ignored. The TOF is controlled via the 
menu setting; see Section 4.2.2. 
SYMBOL SET COMMAND 
Allows the user to disable the DPL Single and Double Symbol Set 
selection commands. 
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL Symbol Set commands are ignored. The Symbol Set selection 
is controlled via the menu setting; see Section 4.2.5. 
CNTRL-CODES (DATA) 
Allows the user to remove control codes (data < 20 Hex) from the 
data fields. The selected line terminator is processed.  
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL Control Code (SOH, STX, CR, ESC, and ^) functions are 
ignored. 
 STX-V SW SETTINGS 
Allows the user to disable the DPL software switch setting 
commands. 
ENABLED 
Normal printer operating mode. 
DISABLED 
DPL option-enable command (<STX>V) is ignored. 
MAX LENGTH COMMAND 
Allows the user to disable the DPL maximum label length 
command. 
ENABLED 
Normal printer operating mode. 
DISABLED 
The DPL <STX>M command is ignored. Maximum label length is 
controlled via the menu setting; see Section 4.2.2. 










