5.1.2 Standard Calibration 
Perform the Standard Calibration when ‘Cannot Calibrate’ or ‘Uncalibrated’ is displayed. During the 
process, the printhead assembly can be raised for visual access. In addition, displayed sensor readings can 
be used to indicate the best position over the media, which is helpful when using small, position-critical 
TOF notches or marks. Three readings are required: 
•  Empty:  No media in the sensor. 
•  TOF Mark:  Only the backing, notch, or reflective mark in the sensor. 
•  Paper:  The label (with the liner attached) in the sensor. 
Follow the steps below to perform a Standard Calibration: 
Step  Action  Displayed Message  Comment 
1 
Turn ‘On’ the printer. 
Wait until the printer 
initializes (about six seconds). 
CANNOT CALIBRATE 
-Or- 
UNCALIBRATED 
(Media should be loaded and 
the ‘Sensor Type’ set.) 
2 
Press the 
MENU
 Key. 
MEDIA SETTINGS 
The Menu Window will 
appear. 
3 
Press the 
ENTER
 Key. 
MEDIA TYPE 
See Section 4.2.2 for menu 
items. 
4 
Press the 
Key to scroll 
to ‘Sensor Calibration’. 
SENSOR CALIBRATION 
Press the 
ESC
Key to abort this procedure. 
5 
Press the
ENTER
Key. 
PERFORM CALIBRATION 
You are beginning the 
calibration procedure. 
6 
Press the 
ENTER
Key. 
Remove the media from the 
Media Sensor then press any 
key.    
!
REMOVE LABEL STOCK 
PRESS ANY KEY <yyy>
Sets the ‘empty’ value - where 
‘yyy’ is a numerical value 
representing the current sensor 
reading. 