Operator`s manual
A-Class  79 
5.1.3  Advanced Entry Calibration 
Advanced Entry Calibration is an alternate calibration method for special-case media types. This is a two-
part procedure: (1) recording the sensor readings for the label using differing algorithms; and, (2) 
selecting the best result, re-sampling, and then entering those values. 
&
Advanced Entry Calibration will override all previous calibration settings. Use this method ONLY if the 
Standard Calibration procedure has failed. 
Follow the steps below to perform an Advanced Entry Calibration: 
Step  Action  Displayed Message  Comment 
1 
Turn ‘On’ the printer. 
Wait until the printer 
initializes (about six seconds). 
CANNOT CALIBRATE 
-Or- 
UNCALIBRATED!
(Media should be loaded and 
the ‘Sensor Type’ set.) 
2 
Press the 
MENU
 Key. 
MEDIA SETTINGS 
The Menu Window will appear. 
3 
Press the 
ENTER
 Key. 
MEDIA TYPE 
See Section 4.2.2 for menu 
items. 
4 
Press the 
Key to scroll 
to ‘Sensor Calibration’. 
SENSOR CALIBRATION 
Press the 
ESC
Key to abort 
this procedure. 
5 
Press the
ENTER
Key. 
PERFORM CALIBRATION 
You are entering the calibration 
submenu. 
6 
Press the 
 Key to scroll 
to ‘Advanced Entry’. 
ADVANCED ENTRY !
You are entering Advanced 
Entry Calibration. 
7 
Press the 
ENTER
Key. 
SENSOR LEVELS 
!!
Press the 
ESC
Key to abort 
this procedure. 
8 
Press the 
 Key. 
SENSOR GAIN!
!
!
You are beginning the 
Advanced Entry Calibration. 










