Operator`s manual
A-Class  81 
Advanced Entry Calibration (continued) 
Step  Action  Displayed Message  Comment 
11 
Two Parts, A & B: 
Part A: Proceed according to 
your media type: 
 Die-cut Media: 
a) Remove a label or two 
from the liner material. 
b) Reinstall the media. 
c) Place only the liner under 
the sensor. 
d) Position the Eye Mark 
over the middle of the liner; 
see Section 3.5. 
 Notched Media: 
Position the Eye Mark over 
the center of the notch; see 
Section 3.5.  
 Reflective Media: 
Position the Eye Mark over 
the center of the black mark; 
see Section 3.5. (The black 
mark must be facing down.) 
Part B: Press the 
ENTER
 Key to 
select the Gain Number 
(denoted by an ‘*’) and then 
record the sensor reading 
(‘yyy’) in your table as a TOF 
Value. 
Next, press the 
Key to 
increment the Gain Number. 
Repeat Part B of this step to 
find the TOF Value for each of 
the Gain Numbers (00-32). 
GAIN TRAN <yyy> 
*00 <0 – 32>
- Or, for reflective media: 
GAIN REFL <yyy> 
*00 <0 – 32> 
!!
!
Where ‘yyy’ is a numerical 
value representing the current 
sensor reading: useful in 
locating the best sensor position. 
 Note: Never position the 
sensor over a perforation when 
recording a sensor reading. 
 Note: Do NOT move the position of the Media Sensor after it has been adjusted. 










