Operator`s manual
82  A-Class 
Advanced Entry Calibration (continued) 
Step  Action  Displayed Message  Comment 
12 
From the data collected in 
Steps 10 & 11, where both the 
sensor readings are above 20, 
subtract the Label Value from 
the corresponding TOF Value. 
Record these as Difference 
Values in the table. 
From the resulting list, locate 
the largest Difference Value 
(see the example below). Its 
associated Gain Number will 
provide the best algorithm for 
your media. 
GAIN TRAN <014> 
*32 <0 – 32> 
- or, for reflective media: 
GAIN REFL <014> 
*32 <0 – 32>
!
Both sensor values must be 
above 20
. 
Gain 
Number 
Label 
Value 
TOF 
Value 
Difference 
Value 
00 255 254  1 
01 251 240 11 
02 241 213 28 
03 231 182 49 
04 219 150 69 
05 212 119 93 
06 200 88 112 
07 189 58 131 
08  178  32  146 
09 167 19  N/A 
10 156 17  N/A 
… … … … 
31 116 14  N/A 
For example, if your 
compiled data had 
the values shown in 
this table, Gain 
Number 8 would be 
chosen because it 
has the highest 
Difference Value 
(146), where both 
the Label Value and 
the TOF Value are 
above 20. 
32 112 14  N/A 
Step  Action  Displayed Message  Comment 
13 
Using the   Key, select the 
Gain Number determined in the 
previous step. 
Press the 
ENTER
 Key to select 
the setting. 
GAIN TRAN <yyy> 
*08 <0 – 32>
- Or, for reflective media: 
GAIN REFL <yyy> 
*08 <0 – 32>
!
This example uses Gain Number 
8. 
Selection is denoted with an 
asterisk (*). 