Operator`s manual
A-Class  83 
Advanced Entry Calibration (continued) 
Step  Action  Displayed Message  Comment 
14 
a) Place the media in the Media 
Sensor. Record the sensor 
reading and label it ‘P’ 
(paper). 
b) Place the liner, mark, or 
notch in the Media Sensor. 
Record the sensor reading and 
label it ‘G’ or ‘M’ (Gap or 
Mark). 
c) Remove all media. Record 
the sensor reading and label it 
‘E’ (Empty). 
(See the example below.) 
GAIN TRAN <yyy> 
*08 <0 – 32> 
- or, for reflective media: 
GAIN REFL <yyy> 
*08 <0 – 32>
!
Where ‘yyy’ is a numerical 
value representing the current 
sensor reading.
15 
Press the 
ESC
Key followed 
by the 
 Key. 
SENSOR LEVELS 
The sensor readings must now 
be entered into the printer. 
Paper  Gap (or Mark)  Empty 
For example, at Gain Number 8, 
these were the sensor readings 
for each of the media conditions. 
(Actual readings will vary.) 
198 
084 
014 