Operator`s manual
84  A-Class 
Advanced Entry Calibration (continued) 
Step  Action  Displayed Message  Comment 
16 
a) Press the 
ENTER
 Key. 
b) Using the 
 Key, set 
the ‘Paper’ level to the value 
determined in the previous 
step. 
c) Press the 
ENTER
Key to set 
the entry (indicated by the 
‘*’) and advance the menu. 
d) Repeat for the ‘Gap’ (or 
‘Mark’) value, and then the 
‘Empty’ value.
PAPER SENSOR LEVEL 
P* 198 G*000 E*000 
 
GAP SENSOR LEVEL 
P* 198 G*084 E*000 
 
EMPTY SENSOR LEVEL 
P* 198 G*084 E*014 
!
!
-Or, for reflective media: 
!
PAPER SENSOR LEVEL 
P* 015 G*000 E*000 
 
GAP SENSOR LEVEL 
P* 015 G*181 E*000 
 
EMPTY SENSOR LEVEL 
P* 015 G*181 E*213 
!
!
!
The selection will change to 
indicate the item for entry. 
17 
Press the 
ESC
 Key to exit the 
menu. 
When prompted, press the 
ENTER
Key
to save your 
changes and return to Ready 
Mode. 
SAVE CHANGES 
ENTER KEY = YES!
!
From ‘Ready’, press the 
FEED
Key. The printer will advance 
the next label to the TOF 
position. If a problem occurs, 
see the note below. 
 Note:  If the Advanced Entry Calibration fails, try the following procedure: 
  Re-enter the Menu. Go to 
 Media Settings 
 Calibration 
 Advanced Entry 
 Sensor 
Gain and lower the selected Gain Setting number by one (to desensitize the sensor). Select the new Gain 
Setting, save the changes, and exit the menu. Test your media at the new setting. If necessary, repeat the 
procedure until a usable media setting is obtained. 










