Operator`s manual
I-Class  95 
Fault Messages (continued) 
Fault Messages 
Displayed Message  Description  Action(s) 
TOP OF FORM FAULT 
The printer could not find 
the TOF within the 
maximum label length 
setting, or TOF occurred in 
an unexpected place. 
 Note: When using 
reflective media, this fault 
is given for an Out of Stock 
condition. 
If media is moving: 
1) Press the FEED Key. It may be 
necessary to re-calibrate the 
printer; see Section 5.2. 
2) The Media Sensor may be out 
of position. Readjust it; see 
Section 3.3. 
3) The media may not be 
properly loaded. Reload 
media, ensuring that the 
Media Guide is properly 
positioned; see Section 3.2. 
4) The Leveling Cam may be 
improperly adjusted; see 
Section 5.4.1. 
5) The label may be longer than 
the value entered. Check the 
Media Settings / Maximum 
Label Length; see Section 
4.2.2. 
6)  The Media Sensor may be 
obstructed. Check and 
carefully remove any 
obstruction (labels, paper 
dust, adhesive, etc). 
If media is not moving: 
The printhead assembly may not 
be locked. 
VERIFIER FAULT 
The Verifier could not pass 
a bar code. 
 Note: This is normal 
when a bar code is 
unreadable. 
Simultaneously press the ENTER 
and F1 Keys on the Verifier to 
clear the fault. If the fault 
persists, consult the option’s 
instructions. 