Operator`s manual
I-Class  113 
Appendix D 
Configuration Files 
With application version 5.01 and above, the printer can save and restore complete printer 
settings, including media calibration parameters, in internal Configuration Files. Here are the 
highlights and restrictions of the feature:  
•  Eliminates the need to repeat the manual steps of a special printer setup, making 
future changeovers faster and easier. 
•  Can be setup, saved, and restored either from the host or via the menu as “C-type” 
files on Module Y under unique filenames of up to nineteen characters in length. 
•  Enables the host, via special DPL commands, to control parameters previously 
accessible only from the Control Panel. 
 Note:  If file sharing among printers, do not include unique parameters (such as 
calibrations and adjustments).  
When using the Control Panel to save a configuration file (see Section 4.2.5), the keypad 
functions are as follows: 
   
The DOWN ARROW Key scrolls down through the 
alphanumeric, underscore, and delete character
. 
   
The UP ARROW Key scrolls up through the alphanumeric and 
underscore characters, and the delete function. 
   
The ENTER Key accepts the displayed character and 
advances the cursor.  
   
The ESCAPE Key saves the displayed file.  