Operator`s manual
62  I-Class 
Three samples are required: 
•  Empty: Nothing in the sensor. 
•  Gap (or Mark): The media liner, notch, or reflective mark in the sensor. 
•  Paper: The label (and liner, if any) in the sensor. 
With the correct SENSOR TYPE selected (see Section 4.2.2), perform a Standard Calibration 
as follows: 
Step
Action  Displayed Message  Comment 
1  Turn ON the printer. 
UNCALIBRATED 
Wait briefly, about six 
seconds, for the printer 
to initialize. 
2 
Press the 
 Key, and 
then raise the printhead 
assembly. 
MENU MODE 
MEDIA SETTINGS 
You are in MENU MODE. 
3 
Press the 
 Key. 
MEDIA SETTINGS 
MEDIA TYPE 
You are in MEDIA 
SETTINGS. 
4 
Press the 
 Key then 
scroll to SENSOR 
CALIBRATION. 
MEDIA SETTINGS 
SENSOR CALIBRATION 
Press the 
 Key to 
cancel this procedure. 
5 
Press the 
 Key. 
SENSOR CALIBRATION 
PERFORM CALIBRATION 
You are beginning the 
procedure. 
6 
Press the 
 Key, and 
then press any key. 
REMOVE LABEL STOCK 
PRESS ANY KEY <yyy> 
No media should be in 
the sensor. This sets the 
Empty value, where 
“yyy” is the current 
sensor reading. 