Operator`s manual
70  I-Class 
Advanced Entry Calibration (continued) 
Step
Action  Displayed Message  Comment 
17 
After all entries have been 
made, press the 
Key 
to back out of the menu and 
then press the 
Key
to save the settings and 
return to the Ready Mode.
SAVE CHANGES? 
ENTER KEY = YES 
From READY, press the 
FEED Key to advance to 
the next label TOF. 
 Note:  If the Advanced Entry Calibration fails, enter MEDIA SETTINGS / CALIBRATION / 
ADVANCED ENTRY / SENSOR GAIN and lower the selected Gain Number by one. 
Select the new Gain Number then save the changes and exit the menu. Retest 
your media. If unsuccessful, repeat the procedure until a usable gain is 
obtained. 
5.3 Reset Methods 
There are three reset methods, each with a different affectivity. Proceed according to the 
desired result: 
5.3.1 Soft Reset 
To clear any temporary host settings, press and hold the CANCEL Key for approximately 
four seconds. 
5.3.2  Level One Reset 
To return the factory default settings or (if saved) a Factory Setting File, turn OFF the 
printer. Press and hold the PAUSE and CANCEL Keys while turning ON the printer and until 
the SYSTEM RESET message flashes. 
 Note:  The same as selecting SET FACTORY DEFAULTS; see Section 4.2.5. 
5.3.3  Level Two Reset 
To return the firmware default settings and clear all parameters, turn OFF the printer. Press 
and hold the PAUSE, FEED, and CANCEL Keys while turning ON the printer and until the 
SYSTEM RESET message flashes. 
 Note:  Calibration is required; see Section 5.2. 