User manual
The Automation Control screen seen in the above diagram is split into 4 sections;
 Auditorium : These are external triggers that effect the theatre, such as lights, masking 
and doors.
 Audio : These are controls that effect the audio processor, such as the volume, mute and 
input selections.
 Display : These are external triggers that effect the display or projector.
 Theatre State : This section of the automation screen is made up of one button only. It 
shows the <Macro>s that can be run. Please see the Macro Section for more information.
List  All  is a  debug  tool   used   by   support   engineers   to   find   problems   in   the   automation 
configuration. 
Lamp Hours is deprecated and will be removed in future releases.
The automation GUI remembers the last known state of a trigger device, e.g. Lights:UP indicates 
that the lighting system was last sent the “UP” message.  This helps support engineers to debug the 
automation system by making clear to the engineer that a message has been sent, even if a resulting 
action on the dCine has not occurred. For example, if the automation GUI screen says lights should 
be down but you observe they are still up, you can deduce that the message was lost if you have 
evidence that the automation did trigger the event. 
The automation trigger list also contains a  special  “List  All”  button  that  is used  to  debug  all 
automation triggers.
Copyright©2012 digitAll Pty Ltd 32