UM-0085-B09 DT80 Range User Manual Page 399
RG
Error Number – Description
Cause/Action
Error Category
Syntax Operation Memory Reading Hardware
E105 Invalid PROFILE section/key name
Check spelling of section and key name in PROFILE
command
E106 Invalid PROFILE value
Check that value being set in PROFILE command is
valid
E107 Counter is already used as a trigger
The specified counter is already used as a schedule
trigger and cannot be used again.
E109 File IO error: detailed description
An error occurred while reading or writing to a file on
one of the drives (A: or B:). The detailed description will
contain exact details of the error type. For example, a
write-protected file cannot be written to.
E110 Error accessing storefile: detailed
description
An error occurred while reading or writing to a storefile
containing logged data. The file may be corrupted.
E112 Parameter/option conflict
The specified combination of command parameters or
channel options are not valid
E113 Schedule option error
Invalid schedule option specified
E114 Command parameter error
Invalid parameter specified for a command
E115 Serial sensor control string error
Invalid syntax within serial sensor control string
E116 Cannot log: detailed description
The DT80 cannot log data for one or more schedules
for the indicated reason
If the problem was that an existing job of the same
name had logged data/alarms then you need to give the
new job a different name, or delete the old job’s data
using DELDATA/DELALARMS
E117 Incompatible schedule store units and
trigger
You can only specify storefile size by time (e.g. 12
hours data) if the schedule trigger is time based.
E118 Error accessing drive
x
:
detailed
description
The indicated drive (A: or B:) could not be accessed
Media may be absent, not formatted or faulty.
E119 No matching storefiles found
There are no storefiles for the specified job/schedule
E122 Command incompatible with configured
port function
nSERIAL channel or trigger defined, or SSDIRECT
command used, and specified serial port has not been
configured as a serial channel in the profile
E123 SSDIRECT mode already active
SSDIRECT command was issued but SSDIRECT mode
is already active on another comms port. Use
ENDSSDIRECT to cancel SSDIRECT mode.
E124 Modbus transaction failed
could not establish connection to Modbus slave device,
or no response to request
E125 - Modbus - write attempt to read-only
register
Modbus discrete inputs and input registers (types 1 and
3) cannot be written to using an expression
E126 - Modbus not supported on this channel
Modbus channel should be 1,2,3 or 4