Instructions
UM-0085-B09 DT80 Range User Manual Page 280
RG
• Hardware Reset Hole (P273)
• External 10-30VDC Input Terminals (P286)
• Battery Charger Terminals (not present on DT82E/ 82EM/ 80L/ 80LM/ 85L/ 85LM/ 85GL/ 85GLM) (P286)
• 10-30VDC Plug Pack Connector (P286)
A threaded hole is also provided as an earthing point. This is internally connected to DGND. On some models, this point
also acts as a protective ground (indicated by the Earth symbol enclosed within a circle). See Grounding (P286) for more
information.
Right Side Panel (DT8xM only)
Figure 113: DT8xM Right Side Panel
DT80 models with integrated modem have modem related interfaces on the right side panel. From left to right:
• SIM card slot. Be sure to slide the locking tab into place after inserting the card
• Indicator LED (red). On indicates that the modem is powered on, flashing indicates that the modem is
connecting or connected to the mobile network
• Diversity antenna connector. This is a receive-only antenna connection, which can provide improved receive
signal level when operating on a 3G network
• Main antenna connector. The supplied external antenna cable should be connected here. To minimise
interference, the actual antenna should be located at least 500mm away from the logger
A threaded hole is also provided as a functional earth point. This is internally connected to DGND.
Right Side Panel (DT8xW only)
Figure 114: DT8xM Right Side Panel