KEYS DOWNLOAD
To download the Acquirer Initial Keys (AIK) the PINPAD has to be set in Keys Download Mode, in
which it exchanges information in a secure way through the RS-232 interface using proprietary
communication protocol.To exit the mode the C button has to be pressed.
CLEAR DEA KEYS
Deletes the customer’s DEA key hierarchy.
EXIT
Exit the service menu forwarding the control to the application.
APPLICATION DOWNLOAD MODE
To enter application download mode on the BLUEPAD-55 v2, the button UP has to be maintained
pressed while switching on the PINPAD. A characteristic sound is played and on the display appears
the name and version of the Secure Boot Loader.
The message - MODE: FW/APP is displayed and the PINPAD listens for application download
commands on the serial interface.
When application download is initiated, on the display is shown the progress in percentages of the
downloading process.
To exit the mode, press C or buttons.
The Application download process shall not be interrupted to prevent memory corruption. If the
buttons C or are pressed during the downloading process, the application integrity checking will
fail on booting up and process will have to be repeated.
COMMUNICATION PARAMETERS
The default RS232 serial port communication parameters are the following:
115200bps
8bit
2stop bit
no parity
The default Bluetooth serial port communication parameters are the following:
115200bps
8bit
1 stop bit
no parity
The default USB VC serial port communication parameters are the following:
115200bps
8bit
1 stop bit
no parity