Manual

8
Changing the Filter Cartridge
1. Turn off the water ow to the cartridges at the valve, tank or tap.
2. Release the pressure by opening a tap downstream, or use the pressure relief
valve that is available in the lid of the lter housings.
3. Unscrew the bottom housing from the lid* and remove the used cartridge and
discard or wash. The inside of the lter housing and the lid should be checked for
cleanliness - they will usually need to be cleaned or sanitised - use hot water and
dishwashing liquid, thoroughly scrub all surfaces and then rinse.
4. Check that the o-ring is in position in the top of the housing base, lubricate with
a coating of white petroleum jelly (Vaseline), place the o-ring into the groove and
with two ngers wipe the o-ring down into the groove. Do not wipe the o-ring clean
of lubricant after it has been properly seated in the groove because the lubricant
prevents “crawling” of the o-ring during the tightening of the lid and thus prevents
water leaks.
5. Screw the housing onto the lid and hand tighten. Open the tap downstream of the
lter and then open the inlet valve.
*The cartridge spanner supplied with the unit may help if the housing is tight.
CAUTION: The housing must be protected against freezing. Failure to do so
may result in cracking of the housing and water leakage.
WARNING: CAREFULLY AND GENTLY TIGHTEN WITH HOUSING SPANNER
as the bowl should only be tightened enough to avoid water leaking during
operation.
WARNING: If the water system is not going to be used for extended periods,
the cartridge should be removed from the housing and replaced with a new or
cleaned cartridge when the system is used again.
IMPORTANT: When opening the lter housing to install or change the
cartridge (element) it is common for the o-ring seal to lift out of the groove
and, at times, it may even stick to the cap.
CAUTION WHEN INSTALLING
1. This is a plastic product with a female thread. If you cross-thread a male
tting, and/or you over pack with sealing tape, you could do permanent
damage.
2. If you use a tapered thread male tting do not over tighten.
3. No warranty claims will be considered for damage due to incorrect installation.
Your new Aquashield Centurion system incorporates a Sterio® includes a lamp
failure system design feature that enables you to be warned of a lamp failure by :-
1. A lamp failure LED.
2. An audible alarm.
In addition when the alarm “beeps” on and off, the lamp is due to be changed so that
effective treatment is maintained.