User Manual
Technical Data
OPERATING PERFORMANCE & MEDIA REQUIRED
Description
Sand
Required
(kg/bags)
Zelbrite
Required
(kg/bags)
Max.
Flow Rate
(lpm)
Min Backwash
Flow Rate
(lpm)
6 Hour
Turnover
(litres)
Filtration
Area
(m
2
)
CCF 18 45/3 34/3 135 90 48,600 0.16
CCF 21 85/5 64/5 185 123 66,600 0.22
CCF 25 145/8 109/8 260 173 93,600 0.32
CCF 28
215/11 161/11 336 224 120,960 0.41
CCF 32 250/13 188/12 415 277 149,400 0.50
CCF 36 350/18 263/18 520 347 187,200 0.64
Filter Care
The Davey Media Filter is the heart of the pool equipment installation. Proper care
and maintenance will add many years of service and enjoyment to your pool. Keep
the exterior of the lter clean, using a mild detergent and water.
Water Quality
Maintaining balanced water chemistry is important to the life of your pool equipment.
This lter is designed to be used with Pool & Spa water, balanced in accordance
with Langlier Saturation Index, with a pH level of between 7.2 and 7.6 and is
regularly treated with a chlorine sanitising agent with the level not exceeding 3PPM.
Please consult your local pool shop regularly to have your water tested.
Trouble Shooting
Problem Action
Reduced ow of water into
pool.
Check lter pressure gauge. If 40-50kPa
above clean lter reading, perform backwash
(page 5).
If still reduced ow after
backwashing.
Check for blocked or plugged lines which
could restrict ow.
Large quantities of media
returning to the pool.
One of the lower laterals may be damaged.
To correct this condition, the media must be
removed and the lateral replaced.
Pump is operating noisily.
Investigate for a possible air leak in the
suction line, blocked pipes or rubbish in the
pump strainer basket. (Refer to pump manual)
In the event of installation or operation difculties with your product, contact the
supplier from whom the equipment was purchased or your nearest authorised
Davey Pool Equipment Service Centre. For assistance in locating your nearest
dealer contact the Davey Customer Service Centre.