User Manual

– 7 –
Removal of Filter
Should it be necessary to remove the lter, the following procedure should be adopted:-
1. Switch off the pump and remove the plug from the power point.
2. Open all air bleeds in system.
3. Close isolating valves where tted.
4. Remove: piping connection to the pump
piping connection to the pool return
piping connection to waste
NOTE: When making any enquiries about your Davey Filter, be certain to
quote the Model Number from the nameplate on the equipment.
WARNING! Pump suction is hazardous and can trap and drown or disembowel
bathers. Do not block suction. Do not use or operate swimming pools, spas
or spa baths if a suction cover is broken, missing or loose. Two suction covers
and inlets must be provided into every pump to avoid suction entrapment.
Routine Maintenance tasks – to maximise the life of your pool equipment & personal
safety, use this checklist once a week. Turn pump off rst.
a. Make sure that any pressure gauges are in working condition and the operating
pressure is within limits as specied on the product.
b. Make sure that each suction inlet, and main drain has a cover that is securely attached
and in safe working condition.
c. Make sure that all skimmer covers are securely attached and in safe working condition.
These should be replaced every 3 to 4 years.
d. Remove any obstructions or debris from the main drain cover.
e. Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and
debris at least once a week.
f. Remove obstructions and combustibles from around the pump motor.
g. Make sure all wiring connections are clean and that all wiring and electrical equipment
is in good condition. Damaged wiring must be repaired or replaced by a qualied
electrician as soon as damage is discovered.
h. Check water balance and sanitiser levels at your local pool shop.
Small children using the pool or spa must ALWAYS have close adult
supervision.
DANGER - Hazardous suction. Do not block water entry into ltration
system with any part of your body as the pressure can trap hair or body
parts, causing severe injury or death. Do not block suction. Turn off
pump immediately if someone becomes trapped.
Caution! Do not add chemicals directly to the pool skimmer. Adding
undiluted chemicals may damage pump and lter and void warranty.
To avoid explosion and possible severe or fatal injury, lter pressure must
not exceed 280kPa. Do not test lter with compressed air. Check that all
clamps and fasteners are in good condition and are rmly secured before
pressurising system. Never adjust clamps or fasteners while lter is
pressurised.
WARNING:
Always relieve pressure from system before performing any
service work.