Manual

4 9
ECO-SPA
TM
INSTALLATION INSTRUCTIONS
(Refer to diagram next page)
1. Please ensure the EcoSpa™ Control Unit is mounted a minimum of 3 metres
away from the spa water and 1.5 metres above ground level. For a portable
spa,theEcoSpa™unitcanbettedontheinsideofthespasurround,please
ensure easy access.
2. Select mounting point and mark 2 holes 18mm apart. (If the unit is to be
mounted to a brick or concrete wall use a masonry drill bit. Some walls such
aslimestoneorcementrendercandamagealuminium,ifindoubtsealthewall
beforemountingthecontrolunit).Drillthe2holesandxsuitablescrewsto
each hole. Recommended screws are 8 gauge.
3. HangunitviaslotsinthetoprearsectionofEcoSpa™unit.NB:Theadditional
mounting hole at the base of the EcoSpa™ can be used to help secure the unit.
4. Plug power plug from control unit into a suitable weatherproof power outlet.
EnsureappropriateRCDsafetydeviceisttedtomainspower.Donotturn
poweronuntilinstallationiscomplete.Whenusedwithcontroller,pluginto
ozonepositionandsetdipswitchesH&Ito1.
5. Install Manifold for ORP Sensor Probe and Pressure Switch into spa return
line after the pump.
6. Plumb Electrolytic Cell into spa return line injection housing. Plug Cell
connector into the appropriate receptacle in the bottom of the unit. The Cell can
be installed vertically or horizontally. NOTE: ORP Sensor and pressure switch
MUSTbeinstalledpriortotheCellandatleast200mm(8”)fromtheCellinlet,
preferably further away.
IMPORTANT NOTICE: For installations where manifold is not used, the pressure
switch must be installed at suitable point on spa return. If return does not
have enough pressure t the pressure switch between pump return and lter.
The pressure switch should be tapped into a point where the pipe enters a t-
ting to allow a good thread length. Tap size is 1/8” NPT. Take care not to damage
threaded end and use thread tape for a good seal.
FitORPSensorProbeatleast200mm(8”)beforeCell.TotORPSensorProbe
drill hole and tap with a 1/4” BSPF tap. This must be done carefully to ensure a
goodthreadedt.ScrewtheORPSensorProbeintothepipework.Notethatitis
besttottheORPSensorProbeintoatting(elbow,coupling,etc)toensuregood
thread length.
7. Connect the pressure switch to the EcoSpa™ Control Unit via the cable
terminated in two insulated pade connectors. Note that the pressure switch is
not waterproof and should not be exposed to the weather.
8. Connect ORP Sensor Probe to socket under EcoSpa™ Control Unit.
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
AUSTRALIA
Davey Support Centre
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 367 866
Fax: 1300 369 119
Website: davey.com.au
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NEW ZEALAND
Customer Service Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 09 527 7654
Website: daveynz.co.nz
® Davey is a registered trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2012.
Davey
®
Repair or Replacement Guarantee
In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction
within warranty periods beginning from the date of original purchase due to faulty materials or
manufacture, Davey will at our option repair or replace it for you free of charge, subject to the
conditions below.
Davey Guarantee Period
Control Box - Two Years Electrolytic Cell - Three Years ORP Probe - Three Years
Should you experience any difculties with your Davey product, we suggest in the rst instance
that you contact the Davey Dealer from which you purchased the Davey product. Alternatively
you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New
Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim,
Davey will seek to resolve your difculties or, if the product is faulty or defective, advise you on how
to have your Davey product repaired, obtain a replacement or a refund.
Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from
misuse or negligent handling, improper use for which the product was not designed or advertised,
failure to properly follow the provided installation and operating instructions, failure to carry out
maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes, or
unauthorized persons attempting repairs. Where applicable, your Davey product must only be
connected to the voltage shown on the nameplate.
Your Davey Guarantee does not cover freight or any other costs incurred in making a claim.
Please retain your receipt as proof of purchase; you MUST provide evidence of the date of original
purchase when claiming under the Davey Guarantee.
Davey shall not be liable for any loss of prots or any consequential, indirect or special loss,
damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This
limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee
applicable to your Davey product under the Australian or New Zealand legislation and does not
affect any rights or remedies that may be available to you under the Australian or New Zealand
Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major
failure.
Should your Davey product require repair or service after the guarantee period; contact your
nearest Davey Dealer or phone the Davey Support Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call: