Manual
8 5
4. If you operate the EcoSpa in hard water (high calcium hardness) your cell
may build up excessive calcium scale. This can be easily removed by cleaning
it.Tocleanthecell,turnoffthebrominator,disconnectthecellleadsfrom
control box and unscrew the barrel unions from the plumbing. Add 1 part
HydrochloricAcidto10partswaterinasuitablecontainerandimmersethe
cell in this solution. It should not take more than a few minutes to clean. While
the calcium is dissolving off the cell you will notice bubbles. When the bubbling
stops,thecellisclean.
5. Afterafewyearsinnormaldomesticuse,yourEco-SpaElectrolyticcellwill
require replacement. Contact your local Eco-Spa dealer for assistance.
TROUBLE SHOOTING GUIDE:
1. Red “No Flow” light is on but has water ow:
•PipeorCellispartiallyblocked
•Adjustpressureswitch(seearrowsonsideofpressureswitch
– lift lock at back)
2. No display:
•Mainpoweroutletswitchedofforlterpumpnotrunning
•Eco-SpaTMnotpluggedintomainoutletormainoutletpoweroff
•EcoSpanotpluggedintoozoneoutlet
•DipswitchesH&Inotset(referpage6,point4)
•Whenpumpisoff(Ifinstalledwithaspacontroller-thisisnormal)
3. Unsatisfactory Bromine Residuals:
•Faultyoroutofdatetestkit
•ORPControlsettoohighortoolow
•ORPProberequirescleaningorremovalofdebris
•Runningtimestooloworbatherloadtoohigh
•Eco-SpaTMBromineActivatorSaltnotadded
WARNING: If Eco-Spa
TM
probe is disconnected or not properly connected to
control unit then your Eco-Spa
TM
will continue to produce Bromine and may reach
dangerous levels. Always ensure connections are intact and if cell power light is
continually on or you smell high bromine levels in the Spa turn off the Eco-Spa
TM
and check the connections.
9. Add Eco-Spa
TM
Bromine Activator Salt at the rate of 50 grams per 1000 litres of
water. Add normal pool salt at the rate of 2.5kg per 1000 litres of water. Your
Eco-Spa is now ready to use and enjoy. Please note the Eco-Spa
TM
must be
poweredwhenlterpumpisrunning.
10. You must change the spa water regularly and add new Eco-Spa
TM
Bromine
Activator Salt and Pool Salt. The frequency of water changes will be affected
byspause,themorethespaisusedthemorefrequentlythewaterchanges
will be required.
For installations with a Davey Spa Power Controller:
• Themanifoldshouldbelocatedafterthespacontroller.
• TheEcoSpamustbepurchasedwithaspecialAMPcordset.
• TheAMPpowerplugisconnectedtotheDaveyspacontrollerviatheoutlet
labelled “Ozone”.
• TheEcoSpawillthenoperatewhileapumpiscirculatingwaterthroughthe
system.
Suggested Eco-Spa
TM
installation diagram follows, other cell installation
congurations are possible. Refer your Eco-Spa
TM
dealer.
ECO-SPA
TM
INSTALLATION VIEW