User Manual

INSTALLATION AND OPERATING
INSTRUCTIONS
DAVEY POWER MASTER
®
200, 250, 350, 450
(INCLUDING 415V 3 PHASE MODEL)
Please pass these instructions on to the owner of this equipment.
The installation of this product should be carried out by a person knowledgable
in swimming pool plumbing requirements following the Installation Instructions
provided in this manual.
– 2 –
Prior to using this pump you must ensure that:
• Thepumpisinstalledinasafeanddryenvironment
• Thepumpenclosurehasadequatedrainageintheeventofleakage
• Anytransportplugsareremoved
• Thepipe-workiscorrectlysealedandsupported
• Thepumpisprimedcorrectly
• Thepowersupplyiscorrectlyconnected
• Allstepshavebeentakenforsafeoperation
AppropriatedetailsforalloftheseitemsarecontainedinthefollowingInstallation
andOperatingInstructions.Readtheseintheirentiretybeforeswitchingonthis
pump.IfyouareuncertainastoanyoftheseInstallationandOperatingInstructions
pleasecontactyourDaveydealerortheappropriateDaveyofceaslistedonthe
backofthisdocument.
CongratulationsonyourpurchaseofaqualityproductfromtheDaveyrangeof
PoolandSpaEquipment.Youareassuredofmanyyearsofreliableandefcient
performancefromyourDaveyPowerMaster
®
backedbyDavey’sthreeyear
guarantee.
DaveyPowerMasters
®
havebeendesignedtocirculateswimmingpoolandspa
waterinconditionssetoutintheAustralianStandardforswimmingpoolwaterquality
(AS3633)orequivalent.Theyshouldnotbeusedforanyotherpurposewithoutrst
consultingyourDaveyDealerortheDaveyCustomerServiceCentre.
Daveydesignandbuilditsownelectricmotorsespeciallyforitspumps.The
matchedmotorand“pumpingend”aredesignedtoprovidethequietestoperation
whiledeliveringmaximumwaterow.
Davey’stotallyenclosedfan-cooledmotorincorporates“autostart”overload
protectionwithabuilt-inautomaticthermostatdesignedtoprotectthemotorfrom
overheating.
EveryDaveyPowerMaster
®
isthoroughlywatertestedagainstanumberofow,
pressure,voltage,currentandmechanicalperformanceparameters.Davey`s
advancedpumpmanufacturingtechnologyprovidesreliableandefcientpumping
performancethatlastsandlasts.
Location
Thepumpshouldbelocatedasclosetothewateraspracticableandmountedon
armbaseinawelldrainedposition,highenoughtopreventanyooding.Itisthe
installer’s/ownersresponsibilitytolocatethepumpsuchthatthenameplatecanbe
easilyreadanditcanreadilyaccessedforservice.
Weather Protection
Itisrecommendedthatthepumpisprotectedfromtheweather.Enclosuresshould
beventilatedtopreventcondensationbuild-upandallowafreeowofairforthefan
cooledmotor.
Power Connection
DaveyPowerMasters
®
aresuitableforconnectiontoanominal240(for415volt
refertopage7)volt50Hzpowersupplyandareequippedwithaexand3pinplug.
Ifapoweroutletisnotavailablewithin3metresofthepump,a3pinpowerpointin
asafe,dryplace,mayneedtobeprovidedbyanelectrician.Extensioncordsare
unsafearoundpools-andshouldbeavoided.Ifthesupplycordofthisproductis
damageditmustbereplacedbythedealerormanufacturer,withgenuineDavey
spares.
–3–
Pipe Connection
Abarrelunionisprovidedforconnectingtothepipingfromthepool.
ThepumpsaredesignedtoacceptthefollowingPVCPipes:
Model InletPVC Position OutletPVC Position
PM200/250 40mmpipe ID 40mm ID
or50mmtting OD 50mmtting OD
PM350 40mmpipe ID 40mmpipe ID
or50mmtting OD 50mmtting OD
or50mmpipe ID 50mmpipe ID
PM450 50mmpipe ID 50mmpipe ID
Theuseofanypipesmallerthanthosespeciedaboveisnotrecommended.
Suctionpipingshouldbefreefromallairleaksandanyhumpsandhollowswhich
causesuctiondifculties.
Thedischargepipingfromthepumpoutletshouldbeconnectedtotheinlet
connectionontheswimmingpoollter(usuallyattheltercontrolvalve).
NOTE: Power Master
®
Pool Pumps are tted with an internal check valve to
reduce reverse ow of water through the pump.
Warning! Ensure that an electrical isolation switch is located with easy
access so that the pump can be switched off in an emergency.
The ttings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability
before use.
Children should be supervised to ensure that they do not play with the
appliance.
Davey Water Products recommends that all installations are tted with
earth leakage or residual current protection devices.
CAUTION: In the interest of safety, we advise that all brands and types of
pool pumps must be installed in accordance with AS3000 wiring rules or
equivalent.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
If the pump and lter are located below pool water level, it is necessary
to t isolating valves in the pipe between the pump and the skimmer box
and in the return pipe from the lter to the pool.
Barrel unions need to be hand tightened. No sealant, glues or silicones are
required.
WARNING: Failure to follow these instructions and comply with all applicable
codes may cause serious bodily injury and/or property damage.
Davey
®
Repair or Replacement Guarantee
In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction
within three years of the date of original purchase due to faulty materials or manufacture, Davey will
at our option repair or replace it for you free of charge, subject to the conditions below.
Should you experience any difculties with your Davey product, we suggest in the rst instance that
you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can
phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or
send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to
resolve your difculties or, if the product is faulty or defective, advise you on how to have your Davey
product repaired, obtain a replacement or a refund.
Your Davey Three Year Guarantee naturally does not cover normal wear or tear, replacement of
product consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting
from misuse or negligent handling, improper use for which the product was not designed or
advertised, failure to properly follow the provided installation and operating instructions, failure to
carry out maintenance, corrosive or abrasive water or other liquid, lightning or high voltage spikes,
or unauthorized persons attempting repairs. Where applicable, your Davey product must only be
connected to the voltage shown on the nameplate.
Your Davey Three Year Guarantee does not cover freight or any other costs incurred in making a
claim. Please retain your receipt as proof of purchase; you MUST provide evidence of the date of
original purchase when claiming under the Davey Three Year Guarantee.
Davey shall not be liable for any loss of prots or any consequential, indirect or special loss, damage
or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation
does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to
your Davey product under the Australian or New Zealand legislation and does not affect any rights or
remedies that may be available to you under the Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major
failure.
Should your Davey product require repair or service after the guarantee period; contact your nearest
Davey Dealer or phone the Davey Customer Service Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
P/N 48717-10 supersedes P/N 48717-9
AUSTRALIA
Customer Service Centre
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 367 866
Fax: 1300 369 119
Website: davey.com.au
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NEW ZEALAND
Customer Service Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 09 527 7654
Website: daveynz.co.nz
® Davey & Power Master are registered trade marks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2011.

Summary of content (2 pages)