Instruction Manual

7
Priming and Operation
1. Remove priming plug and ll
casing and suction line (on
ooded suction, simply open
gate valve to pump). When full,
replace priming plug.
2. Ensure outlet nearest
to pump is open.
3. Ensure all valves in suction line
are open.
To Reset if Pump switches out in Pump Protection Mode
1. Switch off power.
2. Make sure pump is primed.
3. Open tap, switch on power.
4. Close tap and pump will stop.
4. Switch on power - The
status indicator will
be illuminated and
the pump will run.
See section: “Start Up
Procedure”. A full ow
of water should be
discharged from the
open tap.
5. If the pump stops with the
tap open see troubleshooting
checklist.
6. Close the open outlet or tap and
the pump should stop after a few
seconds.
Start Up Procedure
Power the system and in 2 seconds it will display the software variant.
Press ENTER to start system without changing any of the factory pre-sets.
Press + only if you need to alter any of the factory pre-sets.
HCW/MT 19/02/07
**By MAC3 SpA**
Installation (+)
Start (Enter)