User's Manual

4
3. Mounting Endpoints
Parts/Tools Required
U9100-series endpoint(s) (Headset Stations/Wireless Gateways)
M9110FM Flush-Mount Kit (44004G-02, optional)
Pencil/Pen
Drill
13/32-inch Drill Bit
#8 Mounting Screws (customer supplied)
Nuts (customer supplied)
Lock-washers (customer supplied)
Procedure
Location Considerations
Select a location on a flat surface that is out-of-the-way, and provides adequate room to attach all
cables. The U9100-series endpoints are immersion-proof (IP67). However where possible the
mounting location should be chosen to minimize direct exposure to the elements.
Alternately, the endpoints may be flush-mounted with the optional flush-mount kit (M9110FM,
44004G-02).
Mounting
Position the endpoint on the surface to be mounted and mark the (4) hole locations.
Drill the (4) holes with 13/32-inch drill bit.
Mount the endpoint with #8 mounting screws and nuts/lock-washers (customer supplied).