Using the GroWeather
Page 50 GroWeather Manual
Setting the Dew-Point Alarm
The dew-point alarm is a special alarm that is triggered when the temperature
comes within 2˚F of the dew-point.
1. Press DEW to display the current dew-point.
2. Press ALARM to display the dew-point alarm threshold.
3. Press ENTER to activate the alarm.
There is only one threshold for the dew-point alarm (2˚F/1˚C) which appears
in the display when you press ENTER. Pressing ENTER again has no effect.
DEW-POINT ALARM (2˚F)
4. Press DEW to save and exit.
The alarm is now set and will sound when the temperature comes within
2˚F of the dew-point.
To Silence an Alarm
To silence an alarm that has been triggered, press CLEAR. The beeping sound
stops, though the alarm is not cleared. The word ALARM and the function trig-
gering the alarm remain on the display until alarm conditions are no longer
met or the alarm is cleared (as explained below). Note, however, that if a sec-
ond alarm is triggered, the unit will begin beeping again.
To Clear an Alarm
1. Press the appropriate key(s) to display the desired weather condition.
Note that, when an alarm has been triggered, the weather condition causing
the alarm will appear on the display automatically (see “The Alarm Dis-
play” on page 47). If more than one alarm has been triggered at once, wait
until the weather condition you want to reset appears on the display and
then press ALARM.
2. Press ALARM as necessary to display the desired alarm threshold (high or low) for
that function.