Alarm Output Module Connected to Interface Cable Adapter Module
The illustration below shows an Alarm Output Module (AOM) connection
made at the Interface Cable Adapter Module (ICAM). The AOM connection
must be made using either the 2’ AOM Cable or a 40’ (12 m) Standard 6-Con-
ductor Extension Cable. You may not extend this distance beyond 40’ (12 m).
Therefore, if the AOM cannot be located within 40’ (12 m) of the Sensor Inter-
face Module (SIM), you will need to connect the AOM to the ICAM instead.
Connect the SIM to the ICAM using up to 100’ of standard 8-Conductor cable
or up to 200’ of industrial 8-Conductor cable. Connect the Console to the ICAM
(instead of the SIM) using a standard 8-Conductor cable. Connect the AOM to
the ICAM using either the 2’ AOM Cable or a 40’ (12 m) Standard 6-Conductor
Extension Cable.
The AOM can drive control circuits such as thermostats or sprinkler control-
lers. To control power equipment such as heaters, motors, etc., you will need to
provide relays or control circuits.
ALARM OUTPUT MODULE CONNECTED TO INTERFACE CABLE ADAPTER MODULE