Instruction Manual

Page 12 Wireless Leaf & Soil Moisture/ Temperature Sta-
Finishing the Sensor Connections to the Station
1. Secure sensor cables to the cable
tie mounts located next to the
grommets.
2. To prevent fraying or cutting of
cables, secure them so they will not whip
about in the wind. Secure a cable to a metal
pole by wrapping electrical tape around
them both. Make sure cables are secure by
placing clips or ties approximately every 3 –
5' (1 – 1.6 m).
Note: Do not use metal staples or a staple gun to secure cables. Metal staples —
especially when installed with a staple gun — have a tendency to cut the cables.
Mounting the Sensor Against a Wooden Surface
To mount the sensor against a
wooden surface, secure the
sensor to the surface using the
#8 wood screws as shown
below.
Cable Tie
When tightening
cable tie, make sure
cables are on top of
cable tie mount.
Cable Tie
Mount
Securing Sensor Cables
Cable Clip
Cable Tie
Securing Cables with Clips and Tie
s
Mounting on a Wooden Surface