Specifications

20 Davis Instruments
EXTENSION CABLES, SURGE PROTECTORS, & DIMENSIONS

IntheUSA,theNationalInstituteof
Standards&Technology(NIST)develops
and maintains the standards of measure-
ment to which all others are ultimately
traced.Numerouscalibrations,tests,
and measurement assurance programs
aredelivereddirectlytoabout10,000
companies.Fromthesecompanies,NIST-
traceable intermediate service providers
arethenextlinkinanetworkthatjoins
togetherthemakersandusersofpreci-
sioninstruments.DavisInstrumentsis
proudtoparticipateinthisnetwork.
Each of our weather stations is carefully
manufacturedinourCaliforniafactory.
ForthoseuserswhorequireNIST-trace-
ability,certificationandrecertification
of new and previously owned sensors
isnowavailable.ForaNIST-certified
VantagePro2add$200.Call,fax,ore-
mail us for complete details.
Anemometers are wind-tunnel tested in
our California factory.


















WirelessVantagePro2Console/Receiver 0.9 160 274 274 >4years
CabledVantagePro2Console&Sensors 8 168 27 27 14months
PerceptionII 7 127 2.5 1.0 6to9months
WeatherWizardIII 6 n/a 3.0 1.5 6to9months
Surge Protector
For upgraded protection against lightning-induced power
surges, power-cross conditions, and ground potential rises,
use surge protectors with any of our cabled weather stations.
See the chart for the number of protectors required for
your installation. Stripping of wires is required.
7767 Surge Protector $18
Surge Protector Shelter
Weather-resistant shelter for surge pro-
tectors (sold separately). Houses up to
two surge protectors. Measures 3½" ×
5¾" × 2¼" (9 × 14.5 × 5.5 cm).
7768 Surge Protector Shelter $28

 

Console 10
2
/5 ×1
1
/2 ×6
1
/5 264×38×156
LCDDisplay 6×3
1
/2 150×90
ISS:AnemometerSide 14
1
/2 ×5
1
/4 ×17
1
/2 370×130×445
ISS:RainCollectorSidewithStandardRadiationShield 11×9×13
1
/2 280×230×340
ISS:RainCollectorSidewithFan-AspiratedRadiationShield 13×9 ×20 330×230×510
Leaf&SoilMoisture/TemperatureStation 5× 2
3
/8 ×7 130×60×180
Temperature Station 5× 2
3
/8 ×7 130×60×180
Temperature/HumidityStation 8
1
/4 ×7
1
/4 ×7
3
/4 210×185×197

Console 5
1
/4 ×5
7
/8 ×3 133×150 ×76
LCDDisplay 4
1
/4 ×1
3
/4 108×45
JunctionBox 3
1
/4 ×1
7
/8 ×
7
/8 82 ×48× 22


Standard4-and6-conductor
cables include waterproof
couplerkitsforjoiningtwo
cablestogether,indoorsor
out. To join standard 8-con-
ductorcables,usean8-pin
cablecoupler(forindooruse
only).Allcablesmayalsobe
joinedusingSurgeProtectors.

TheextensioncableslistedarefortheserialportversionsofWeatherLink.ForUSB
versionsofWeatherLink,addaUSBextensioncable,availablefromyourlocalcom-
putersupplier.(NotavailablefromDavisInstruments.)

Maximum wind speed reading decreases as length of cable from anemometer
tointegratedsensorsuite(forVantagePro2)orconsole(forWeatherWizardIII,
includingjunctionboxcable)increases.At140'(42m),maximumspeedis135
mph(60m/s).At240'(73m),maximumis100mph(45m/s).
7876-008Standard4-Conductor,8'(2.4m)$10
7876-040Standard4-Conductor,40'(12m)$18
7876-100Standard4-Conductor,100'(30m)$40
7876-200Standard4-Conductor,200'(61m)$70
7880-025Standard8-Conductor,25'(7.5m)$15
7880-050Standard8-Conductor,50'(15m)$25
7880-100Standard8-Conductor,100'(30m)$45
7959Eight-PinCableCoupler$5
7895-050Shielded4-Conductor,50'(15m)$25
7895-100Shielded4-Conductor,100'(30m)$48
  

WirelessVantagePro2 40'(12m) Foranemometertointegratedsensorsuite,seenoteabove.
CabledVantagePro2
40'(12m) Foranemometertointegratedsensorsuite,seenoteabove.
100'(30m) 1000'(300m)fromconsoletointegratedsensorsuite.
WeatherLinkforVantagePro2 8'(2.5m) 48'(14.6m)fromdataloggertoserialport.(Serialportversionsonly.)
SolarRadiationSensor 2'(0.6m) 125'(38m)fromsolarradiationsensortointegratedsensorsuite.
UV Sensor 2'(0.6m) 125'(38m)fromUVsensortointegratedsensorsuite.

WeatherWizardIII 8'(2.4m) 125'(38m)fromjunctionboxtoconsole.
WeatherLinkforWizard 8'(2.4m) 50'(15m)fromdataloggertoserialport.
Anemometer 40'(12m) See note above.
RainCollector 40'(12m) 900'(270m)fromraincollectortoconsole,including cable from junction box to console.
Temperature Sensor 25'(7.6m) 300'(91m)fromsensortoconsole,includingcablefromjunctionboxtoconsole.
RainCollectorHeater 50'(15m) 120'(36m)frompowerunittoAC-poweradapter.Requiresterminalblock.
* Actual battery life will vary depending on station setup and usage.

Weather Station
Cable Run
Number of
Surge Protectors
VantagePro2orPro2Plus
AnemometertoIntegratedsensorsuite 2
Integratedsensorsuitetoconsole 2
WeatherWizardIII
Temperature sensor to junction box 1
Raincollectortojunctionbox 1
Anemometer to junction box 2
Junctionboxtoconsole 4