User Manual

iLM8 Live User Manual
33
iLM8 - Live may be configured to alert you to an AES lock loss condition.
AES Lock: Allows the AES Lock alarm to be suppressed or enabled. (Default: Off)
About Menu
Model Number: Displays the model number of the unit.
Serial Number: Displays the serial number of this unit.
Build Number: Displays the firmware build number.
Build Date: Displays the firmware build date.
Hardware Rev: Displays the hardware revision level of this unit.
Firmware Rev: Displays the firmware revision level that is running on this unit.
Eclipse Algorithm: Versions of the Eclipse algorithm.
Eclipse Algorithm Rev: Version of the Eclipse algorithm.
Faults
Although your iLM8 - Live will provide you with years of trouble free service, occasionally problems may
occur. Below is a listing of the most common fault conditions.
No Clock: AES sync has been lost. Please check the source equipment and all cable connections.
Ensure that iLM8 - Live is operating in the proper input mode for your application and is looking for the
source audio on the correct port.
CRC Error: iLM8 - Live has encountered a CRC error in the audio stream. Check that equipment up-
stream of iLM8 - Live is properly configured to output the correct audio stream.
Validity Error: iLM8 - Live has encountered a validity error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream.
Bi-phase Error: iLM8 - Live has encountered a bi-phase error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream.
No Parity Error: iLM8 - Live has encountered a parity error with the audio stream. Check that
equipment up-stream of iLM8 - Live is properly configured to output the correct audio stream