Instruction Manual

M2 User Manual
15
Push “SELECT” switch to increment the menu to the next alarm function.
A L L A L A R M S
O N O F F > S E T U P <
Alarm Output 1 – RF Carrier Loss (alarm based on analog RF signal strength)
Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the
setting. Select “SET” to set this monitor alarm and continue with alarm configuration
menu; select “OFF” to set this monitor alarm function to off. Push “SELECT” to
continue.
R F C A R R I E R L O S S
> S E T < O F F
If “SET” is selected, submenu for “Level” threshold with “LOW”, “MED” and “HIGH”
options is displayed next. “LOW” option sets RF carrier loss threshold for
approximately 10µV (25dBf); “MED” option sets RF carrier loss threshold for
approximately 100µV (45dBf); and “HIGH” option sets RF carrier loss threshold for
approximately 3KµV (75dBf). Use UP and DN switches to toggle the setting and
highlight the desired option.
R F C A R R I E R L E V E L
L O W > M E D < H I G H
Push “SELECT” switch to increment the menu to the next alarm function.
Submenu for “Alarm Delay” with “30”, “60”, “120” and “240” second options is
displayed next. Use UP and DN switches to toggle the setting and highlight the
desired option.
A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S
Push “SELECT” switch to increment the menu to the next alarm function.
Alarm Output 2 – Audio Loss (Silence Detect)
Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the
setting. Select “SET” to set this monitor alarm and continue with alarm configuration
menu; select “OFF” to set this monitor alarm function to off.