3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Specifications ELECTRICAL SPECIFICATIONS Model Rated Wattage* Rated Amperage 120V Rated Amperage 240V 3W735B 2,200 18.3 — 3W736C 4,000 33.3 16.7 3WY44 5,000 41.7 20.8 3WY46 5,000 41.7 20.8 3TE27A 6,000 50 25 3WY45 7,000 60 30 3WY47 10,000 83.3 41.7 * Single-phase, 1.0 power factor NOTE: Ratings apply to SAE standard conditions.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Product Identification Gas Cap/Fuel Gauge F U E L Control Panel F GFCI Receptacle Full Power Selector Switch Roll Cage 12 0 VO LT S RE SE TE T ST FU LL PO WE R 12 ON 0 LY 12 0 24 0V 120 Volt Receptacles 00 HO EN M 00 00 UR S 12 0/2 40 05 1/1 0 VO LT S RE SE T Gas Tank RE SE T Hour Meter 120/240 Volt Receptacle F U E L F Circuit Breaker Choke Lever Fuel Valve Lever Star
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® General Safety Information IMPORTANT: Read these instructions and engine owner’s manual carefully. Become familiar with generator before trying to operate or service it. Know its uses, limitations, and any hazards involved. Improper use of generator can cause severe injury or death from explosion, fire, burns, electrical shock, or carbon monoxide poisoning.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 General Safety Information (Continued) Engine exhaust from this product contains chemicals known, in certain quantities, to cause cancer, birth defects, or other reproductive harm. Guard against burns. Hot engine parts can cause severe injury. Use caution and remain alert when using generator. • Keep children and animals away from generator while it is running or hot.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Generator Features (Continued) from the oil level sensing device. This will cause the oil alert system to shut down engine. See engine owner’s manual for more information. IMPORTANT: Do not move the full power selector switch while powering electrical items. Unplug all items before moving switch. Failure to do so can damage switch.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Generator Features (Continued) RECEPTACLE CIRCUIT BREAKER IMPORTANT: You must press the RESET button firmly and fully. It should lock into place. If the GFCI does not lock into place, do not use receptacle. Contact a qualified electrician for repairs. EL FU 2. If the GFCI receptacle tests okay, restore power by pushing the RESET button back in. The test lamp should work at this time.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Assembly (Continued) BATTERY (MODELS 3WY46, 3WY45, AND 3WY47 ONLY) Battery gives off explosive gases. Keep sparks, flames, and cigarettes away. Do not remove or install battery cables when engine is cranking or running. Only service or use battery in a well-vented area. Battery contains sulfuric acid. Contact with skin or eyes may cause severe burns.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Assembly (Continued) Nut MOUNTING BATTERY TO GENERATOR Battery Mounting Bracket Do not over tighten positive terminal on starter solenoid. Positive terminal could rotate and cut into negative terminal, causing a short. To Engine Block To Starter Solenoid F U E L NOTE: Model 3WY47 battery is located on opposite side as shown (See Figure 16). F F F U E L Battery 1.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Installation FUEL Gasoline presents a hazard of fire or explosion. Gasoline is flammable. Its vapor is explosive. • Keep fuel out of children’s reach. • Refuel generator in a well-vented area. Do not fill fuel tank in the dark. Do not refuel while engine is running. Unhook all electrical loads and shut off engine before refueling. 1.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Installation (Continued) DUST, DIRT, RAIN, AND SNOW Do not use generator outdoors in rain or snow. Do not use generator near standing water or snow. Do not use if generator is wet or damp. Operating generator in these conditions increases the risk of electrocution. Severe injury or death can occur. Do not use generator in extremely dusty or dirty conditions. This will severely affect its life.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Installation (Continued) NOTE: Some motors require nearly the same wattage to run as to start. These items include saws, drills, hair dryers, and food mixers. See Chart 2 for typical appliance wattage examples. 4. Add watts and starting watts (maximum VA) of all items. This total must not be larger than the rated wattage of your generator.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Operation HIGH AND LOW TEMPERATURE OPERATION Air temperature affects generator output. Output drops 1% for each 10° temperature rise above 60° F. Very low temperatures may make the engine hard to start. See engine owner’s manual for more information. Use receptacles properly. Improper use could damage generator. Use only grounded extension cords. Power only grounded or double-insulated items.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Operation (Continued) PRESTART Operate generator on a firm, dry, and clean surface. The surface must be level. Protect generator from heavy dust, sand, dirt, rain, or snow. Do not locate generator near standing water and snow. Make sure area is well-vented. NOTE: You may not need to close choke if engine is warm or air temperature is high. 4.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Operation (Continued) 5. As engine warms up, slowly move choke lever fully to the right (See Figure 28). This opens the choke. On Model 3WY47, the choke will automatically open (See Figure 29). AUTO-IDLE OPERATION ADJUSTING THE IDLE SPEED IMPORTANT: Never start engine with electrical loads connected. Start engine before adding electrical loads. IMPORTANT: Adjust the idle speed only: 1.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Operation (Continued) Always set the idle speed before turning on the auto-idle. If idle speed is not set, the larger resistor on the control board may become hot. Heat from the resistor may damage the protective coating on the control board. 5. Slowly pull solenoid bracket away from engine (on Model 3WY47 this will require bending the bracket slightly). 6.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Operation (Continued) 4. Turn fuel valve lever off. Do this by moving valve lever fully to the left (See Figure 35). Fuel Valve Lever (Off Position) IMPORTANT: Keep generator level when servicing. Never turn generator upside down or stand it on end to service. NOTE: We supply the engine owner’s manual with generator. Refer to that manual for questions concerning engine maintenance and repairs.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Troubleshooting Chart NOTE: See engine owner’s manual for engine troubleshooting. Only a qualified electrical service person should service and repair generator. Use only factory approved repair parts. Symptom Possible Cause(s) Corrective Action Engine will not start 1. Insufficient fuel 1. Fill tank with fresh fuel 2. Oil level low 2.
Dayton Operating Instructions and Parts Manual Models 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Wiring Diagrams Stator Black Receptacle 120V/15A 20A T1 T3 T4 110/120V L1 T2 Capacitor L2 Rotor Yellow Stator White Black Auxiliary Phase Diode Diode Circuit Breaker Yellow Red Green Brown T2 T3 T1 Green/Yellow T4 Main Windings Yellow Black Red Green Figure 36 – Wiring Diagram, Model 3W735B Red Black Red 120/240V 20A Receptacle White Circuit Breaker 25A White T4 Yellow
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Professional-Duty Electric Generators ® Wiring Diagrams White Red Black Red 120/240V 20A Receptacle s1 s2 White • T1 To Solenoid Circuit Breaker 25A Circuit Breaker 20A Black White Hour Meter White Black Green Black Red Green Main Windings Capacitor White T1 T4 T3 Green Red Black Black Red White White LINE T4 Yellow • Circuit Breaker 20A Red Black T3 120V, 30A Re
3W735B Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list 1 Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3W735B Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A. 1 7 2 4 22 5 6 3 20 15 14 21 19 13 17 16 15 7 8 7 13 12 18 9 When replacing diodes, note the positions of polarity bands on each.
3W735B Dayton Operating Instructions and Parts Manual Repair Parts List for Model 3W735B Alternator Assembly Reference Number Description Part No.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual Repair Parts List for Models 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Alternator Assembly Reference Number Description Part No.
3WY47 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3WY47 Dayton Operating Instructions and Parts Manual Repair Parts List for Model 3WY47 Alternator Assembly Reference Number Description Part No. for Model 3WY47 1 Stator † 1 2 Rotor † 1 3 Draw bolt 103188-01 1 4 Fan 103191-01 1 5 Balancing disc 103192-01 1 6 Lifting eyes 103193-01 2 7 D.E. Bracket 103194-01 1 8 N.D.E.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual Repair Parts List for Models 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Fuel Tank and Roll Cage Reference Number Description Part No.
3WY47 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year 36 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3WY47 Dayton Operating Instructions and Parts Manual Repair Parts List for Model 3WY47 Fuel Tank and Roll Cage (Continued) Reference Number Description Part No.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual Repair Parts List for Models 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Control Panel Reference Number Description Part No.
3WY47 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
3WY47 Dayton Operating Instructions and Parts Manual Repair Parts List for Model 3WY47 Control Panel Reference Number Description Part No.
3WY47, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Dayton Operating Instructions and Parts Manual For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P.O. Box 3074 1657 Shermer Road Northbrook, IL 60065-3074 U.S.A.
Dayton Operating Instructions and Parts Manual 3WY47, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Repair Parts List for Solenoid and Control Board Assemblies and Mounting for Models 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Reference Number Description Part No.
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Notes ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ __________________________________________________
Dayton Operating Instructions and Parts Manual 3WY47, 3W735B, 3W736C, 3WY44, 3TE27A, 3WY45, and 3WY46 Notes ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ __________________________________________________
Dayton Operating Instructions and Parts Manual 3W735B, 3W736C, 3WY44, 3WY46, 3TE27A, 3WY45, 3WY47 Dayton Professional-Duty Electric Generators NOTE: The five-year limited warranty below covers all non-engine parts of this generator including the alternator. Honda warrants the engine. See engine owner’s manual for engine warranty information. LIMITED WARRANTY DAYTON FIVE-YEAR LIMITED WARRANTY.