Operating instructions

Dayton Operating Instructions and Parts Manual 5U933A, 5U934A, and 5U935A
2
Dayton Professional-Duty
Electric Generators
®
105966
Specifications
Rated Maximum Rated Amperage Rated Amperage
Model Wattage* VA 120V 240V
5U933A 4000 5500 33.3 16.7
5U934A 5000 6500 41.7 20.8
5U935A 7000 9000 58.3 29.1
ELECTRICAL SPECIFICATIONS
(*) Connect T2 (green) and T3 (black). Measure resistance between T1 (red) and T4 (yellow).
() Resistance between brown and white leads.
(†) Remove diodes to check resistance.
(*) Single-phase, 1.0 power factor.
NOTE: Ratings apply to SAE standard conditions. Reduce ratings 3
1
/2% for each 1000 feet above sea level and 1% for each 10°
Fahrenheit rise above 60°F.
Resistance in Ohms
Stator Stator Rotor Rotor Capacitor,
Main Auxiliary Primary Secondary MFD Diodes (2)
Model Winding * Winding Winding † Winding † 450 Volt 800 Volt
5U933A 0.71 2.17 0.54 2.07 40 70 Amp
5U934A 0.54 1.38 0.61 2.29 50 70
5U935A 0.28 0.78 0.77 2.9 70 70
ELECTRICAL COMPONENT SPECIFICATIONS
120V 120V 120V, 30-Amp 120/240V, 20-Amp 120/240V, 30-Amp 120V Full Hour
Model Duplex GFC1 Twist-Lock Twist-Lock Twist-Lock Power Switch Meter
5U933A Yes Yes Yes Yes No Yes Yes
5U934A Yes Yes Yes Yes No Yes Yes
5U935A Yes Yes Yes No Yes No Yes
RECEPTACLE SPECIFICATIONS
Briggs & Stratton Briggs & Stratton Fuel Fuel Tank Oil Alert Electric Weight
Model Engine HP Model Type Capacity System Start (pounds)
5U933A 9 Vanguard Gasoline 5 gal. Yes No 130
5U934A 11 Vanguard Gasoline 5 Yes No 181
5U935A 14 Vanguard V-Twin Gasoline 5 Yes Yes 263
GENERAL SPECIFICATIONS