Operating instructions

Dayton Operating Instructions and Parts Manual
7
Models 5U933A, 5U934A, and 5U935A
Version B - For Reduction G016.J
®
105966
General Safety Information
(Continued)
IMPORTANT: Do not move the full
power selector switch while powering
electrical items. Unplug all items before
moving switch. Failure to do so can
damage switch.
Model 5U935A does not have this
switch. This model provides full power to
all receptacles.
TrippedNormal
20
20
Figure 8 – Receptacle Circuit Breaker Button
Electric motors need higher starting
current. They require up to 3-times their
rated wattage to start. The starting current
needed may be too high. This can cause
nuisance circuit breaker tripping. To help
prevent this, start electric motors first.
Connect additional items to generator
after starting motors. If this continues to
happen, reduce the total generator load.
HOUR METER
The hour meter is on the control panel.
The hour meter shows the total amount of
time the generator has run (See Figure 7).
Use the time on the hour meter as a guide
for servicing the generator.
Assembly
BATTERY (MODEL 5U935A ONLY)
Battery gives off
explosive gases.
Keep sparks, flames, and cigarettes
away. Do not remove or install battery
cables when engine is cranking or
running. Only service or use battery in
a well-vented area.
Battery contains
sulfuric acid.
Contact with skin or eyes may cause
severe burns. Do not tilt generator with
battery installed. Tilting could cause
battery acid to spill. Wear protective
clothing and face shield when servicing.
Keep out of children’s reach.
If battery acid gets on your skin,
wash with water.
If battery acid gets in your eyes,
flush with water at least 15 minutes.
Call a doctor at once.
Battery acid is poisonous.
If swallowed, drink large amounts of
water or milk. Follow with milk
of magnesia or vegetable oil. Call a
doctor at once.
from the oil level sensing device. This
will cause the oil alert system to shut
down engine.
See engine owner’s manual for more
information.
FULL POWER SELECTOR SWITCH
All models except 5U935A have a full
power selector switch on the control
panel. The switch has two positions: 120
VOLT ONLY, and 120/240 VOLT.
120 VOLT ONLY: This position sends full
power to the 120V receptacles only. 240V
power is not available. Use this position
when powering 120V items only.
120/240 VOLT: This position sends full
power to the 120/240V receptacle. It also
powers the 120V receptacles at reduced
wattage capacity.
Selector
Full Power
120 V
ONLY
120/
240V
Figure 6 – Full Power Selector Switch in
120/240 Volt Position (Models 5U933A
and 5U934A)
Selector
Full Power
120 V
ONLY
120/
240V
Figure 5 – Full Power Selector Switch in
120 Volt Only Position (Models 5U933A
and 5U934A)
Figure 7 – Hour Meter
ELECTRIC START (MODEL 5U935A ONLY)
Model 5U935A has an electric starter. A
battery is not supplied with generator. You
must provide a 12-volt, 32-amp battery.
For more battery information, see Battery
(next column).
RECEPTACLE CIRCUIT BREAKER
All models have four circuit breakers. The
circuit breakers protect the receptacles and
alternator. Overloading generator will trip
circuit breaker. A short circuit in item being
powered will also trip breaker. If this
occurs, unplug electrical load from
receptacle. Let circuit breaker cool down.
Push circuit breaker button to reset.