Manual

DVA MINI Digital Array System
11
ENGLISH
STATE OR
CONDITION OF THE
MODULE
“READY”
LED
“MUTE/PROT”
LED
“SIGNAL”
“LIMITER”
FUNCTIONS OR
DESCRIPTION OF THE
MODULE
Amplifier temperature management
Amplifier temperature
(thermal threshold)
Normal
operation
Cycling
flashing
Normal
operation
Normal
operation
Audio ACTIVE
The amplifier module reduces the volume, in
steps of 0.1 dBm up to a maximum of 6dBm,
as the temperature rises above the safety
threshold.
Generic errors
No power supply (Vac)
detected
ON
A momentary lack of supply voltage is
detected during normal operation
Current overload
ON
ON
A
current overload is detected during normal
operation.
Communication error
with the DSP
ON
Cyclic flashing
(1slow flashes)
A communication error between the
preamplifier and the processor of the audio
signal has been detected.
Incorrect
configuration
ON
Cyclic flashing
(2slow flashes)
The settings of the amplifier module do not
match the hardware configuration of the
module.
Incorrect firmware
ON
Cyclic flashing
(3slow flashes)
The DSP firmware does not match the versi
on
of the pre-amplifier
USB Mode
Bootloader function
ON
They flash alternately
The bootloader function in the pre
-
amplifier is
active
Telemetry ON
They flash alternately
The amplifier module is connected to the USB
port for downloading the telemetry
CONNECTIONS
USB Data Link
The speaker DVA MS12 is equipped with a USB "Service" connector, useful for the firmware
update of the module or to download speaker operation data.
Connecting to the mains supply
Each active speaker features its own power cable. Connection is done by a Neutrik POWER
CON® (Blue) model which permits easy and fast connection to the speaker as well as being an
excellent locking system.
The POWER CON connector acts as the disconnecting device for the power supply and must be
easily accessible after installation and during use of the speaker
The active speaker must be connected to a power supply able to deliver the maximum required
power.
The DVA MS12 is provide on its own power cord.
Main power supply linking
On the rear of the speaker, a Neutrik POWER CON® connector (Grey) offers linking the mains
power supply.
This socket links the power supply to another speaker, thereby reducing the direct connections to
the mains. Maximum amplifier input power is shown on the amplifier panel.
The maximum number of speakers connected to the LINK OUT connector varies depending on the
voltage of power supply used and the type of connected speaker to this socket. Do not exceed in
any case the maximum current / power specified in the data on the panel. This failure can cause