User Manual

Table Of Contents

DVA MINI G2 Code 420120326 REV.1.0
English
CONNECTION AND POWER DAISY CHAIN
The gure below shows a general connection where a module 1 is above a module 2. For this
purpose, use cables with powerCON TRUE1® connectors (not provided).
• Connect the power supply of module 1 AUTO-RANGE MAINS INPUT (A).
• Daisy-chain the power supply from module1 to module 2, connecting MAINS LINK output (B)
of module 1 to AUTO-RANGE MAINS INPUT (C) of module 2.
• Repeat this procedure until connecting the maximum permitted number of the line array
modules (refer to section SPECIFICATIONS).
• Use DBTECHNOLOGIES COMPOSER to set project parameters.
• Make sure that the local parameters of the different modules are correctly set on the single
amplier panels. In particular, check the DSP settings according to design. As an alternative,
all parameters can be remotely edited in real time if the line array connection is carried out
through the RDNet network (AURORA NET). Nevertheless, in this case, project initial settings
should be physically repeated on the modules.
• Transport, through DT-8MINI, the rst 4 modules and DRK-M5 y-bar to the spot in which
the line array will be lifted. Have a second dolly (with no y-bar) ready with other 4 modules
for the following assembly stages of the complete line array.
• Fix the brakes on the dolly wheels.
• Fit the rst 4 modules with y-bar according to the instructions above and to accessory
instructions.
• Hoist the rst 4 modules using a motor and suitable rigging equipment (not supplied) and
then continue with the next modules with the second dolly. The connections suggested are
for information only.
MAINS LINK
AUTO-RANGE
MAINS INPUT
220-240V~ 50-60Hz 1,5A
100-120V~ 50-60Hz 2,5A
220-240V~ (14,5Amax)
3330Wmax
O
O
F
F
F
F
O
N
O
N
100-120V~ (17,5Amax)
1920Wmax
MAINS LINK
AUTO-RANGE
MAINS INPUT
220-240V~ 50-60Hz 1,5A
100-120V~ 50-60Hz 2,5A
220-240V~ (14,5Amax)
3330Wmax
O
O
F
F
F
F
O
N
O
N
100-120V~ (17,5Amax)
1920Wmax
MODULO 1
MODULO 2