User guide
Error Code
674
16
DBX 25 
004
MMI file on the sys-
tem in not compatible 
with the rest of the 
base software
Push software from OLS Upgrade the base 
software with cor-
rected base soft-
ware
DBX 27 
000
The automatic or 
manual date advance 
interface has been set 
with invalid parame-
ters (automatic: date 
change time to mid-
night, or no working 
day in the week; 
Manual: day offset 
exceeds limit).
Modify initialization of date 
advance 
DBX 27 
003
Technical error  Try with Service 
PSD Order a new 
PSD
DBX 29 
002
this message appear 
for system with con-
nected inserter. Mes-
sage Id not in 
dictionary
Check connection between inserter and base
DBX 32 
000
The system didn't 
receive the length 
value from dynamic 
scale
Ask customer to check 
dynamic scale wiring
1 Check connection 
2 Check dynamic 
scale board 
3 Check length sen-
sor
DBX 32 
001
The system didn't 
receive the length 
value from the inserter
Check connection bet-
ween inserter and base
Check connection 
and parameters
DBX 32 
002
The system didn't 
receive the thickness 
value from inserter
Check connection bet-
ween inserter and base
Check the inserter 
connection and 
parameters
DBX 32 
003
The system didn't 
receive the thickness 
value from the dyna-
mic scale
Ask customer to check 
dynamic scale wiring
1 Check connection 
2 Check dynamic 
scale board 
3 Check thickness 
sensor
DBX 32 
004
The system didn't 
receive the oversize 
status from the dyna-
mic scale
Ask customer to check 
dynamic scale wiring
1 Check connection 
2 Check dynamic 
scale board 
3 Check oversize 
sensor
Code Description Helpdesk On site