User guide
Error Code
685
16
DPA 34 
003
The meter is faulted Swap PSD
DPA 35 
000
technical error 
DPA 35 
002
There are two root causes for this message. 
First one the most frequent is: That the message will 
appear if you made credit reset and the transaction is 
not successful and after you try to do a credit reset 
with a different amount from the previous failed credit 
reset. User have to perform a successful credit reset 
with the same amount to ba able any different credit 
reset. Note in every country except Germany the 
user can frank. 
The second root cause may be that: Maximun reset-
ting limit reach Or total credit amount reach
Retry resetting with 
previous amount up 
to successful reset 
transaction.
DPA 36 
000
Handshake between 
server and PSD is 
failed
The system can talk but 
something wrong between 
PSD and back office.
 Remote action: check the 
PSD back office status 
DPA 36 
001
Device unable to con-
nect to spine
Contact back office to know aspirrine server status
DPA 37 
001
Connection with server 
have been set but con-
nection with server 
have been lost
Check machine and wall socket connection wiring
Retry
DPA 37 
002
Connection with server 
have been set but ser-
ver took too many time 
answer
Contact Server support team to check server sta-
tus
DPA 37 
004
Connection with server 
have been set but sys-
tem unable to send 
messages to server
Contact Server support team to check server sta-
tus
DPA 38 
003
Connection server 
failed It's a generic 
message see if there's 
a second message 
more accurate on the 
root cause
Try to get the other error message to understand 
root cause
Code Description Helpdesk On site