User guide
Error Code
696
16
DWA 01 
009
 the "dynamic scale 
entry" sensor is activa-
ted when the batch 
starts
1 Take out the envelope
Pess on OK key to clear the error 
If it is still occurring, may be the sensor needs to 
be replaced
DWA 01 
010
 the dynamic scale 
"oversize" sensor is 
activated when the 
batch starts
1 Take out the envelope
2 Press on OK key to clear the error 
If it is still occurring, may be the sensor is activa-
ted by some light around the machine ( lamp, 
sun, etc..): ask to check , Take out , hide etc.. if it 
is still occurring, may be the sensor needs to be 
replaced: 
DWA 02 
000
the Dynamic scale 
detects a weight of 
more than +/- 400gr 
during the initialization
1 Ask customer to Take out the envelope , and 
power Off, then On the machine (or unplug)
2 If it is still occurring, may be the dynamic scale 
needs to be recalibrated or the load cell to be 
replaced: 
DWA 02 
001
the base board, load 
cell or cabling in bet-
ween is most probably 
damaged 
ask the customer to power 
Off, then On the machine 
(or unplug) if it fails, then 
prepare a tech visit to 
replace the Dynamic Scale 
main board, cable or the 
load cell 
Replace the Dyna-
mic Scale main 
board, cable or the 
load cell 
DWA 02 
002
the Dynamic scale 
analog / digital conver-
ter detects an error 
during the initialization 
ask the customer to power 
Off, then On the machine 
(or unplug) if it fails, then 
prepare a tech visit to 
replace the Dynamic Scale 
main board
Replace the Dyna-
mic Scale main 
board
DWA 02 
003
in service mode: 
during calibration the 
Dynamic scale detects 
a wrong weight
1 There is a default in the weighing platform, "lb" 
is selected instead of "kg”
2 If not Take out the weight 
3 power Off, then On
4 Restart the calibration
5 If not solved, the load cell may be damaged, 
and need to be replaced, 
DWA 02 
005
service mode, during 
calibration, the Dyna-
mic scale detects 
some weight (calibra-
tion failed) 
1 Please Take out the envelope or the weight 
2 Power Off, then On the machine (or unplug) 
3 Then retry the calibration 
4 If not solved, the load cell may be damaged, 
and need to be replaced, 
DWA 02 
006
the weight on the 
Dynamic scale is too 
heavy: over 1000gr or 
2lbs
1Take out the envelope 
2 Press the OK key to clear the message - to mail 
it with the weight platform and use a label 
Code Description Helpdesk On site