User's Manual

6
®
Rear Panel
120V 50/60Hz
1
2 3
54
6
1. IEC AC Power Inlet
Connect the included IEC power cord to this power inlet. The DriveRack PA2 ships from the factory configured for one
of two specified power voltage ranges, they are:
100-120V, 50Hz/60Hz
220-240V, 50Hz/60Hz
NOTE: Ensure the screening under this outlet matches the voltage specification in your country before applying
power to the PA2.
2. Ethernet Port
This RJ45 connector is used for updating the firmware and controlling the PA2 from a networked device using the
free DriveRack PA2 control app. See ‘Network Connections’ on page 9, ‘Networking’ on page 57, and
‘Firmware Updates’ on page 59 for more information on using this port.
NOTE: A DHCP enabled switch or Wi-Fi router is required to assign an IP address to the PA2 for network
control.
3. USB Port
This USB connector is used for updating the PA2’s firmware. See ‘Firmware Updates’ on page 59 for more
information.
4. Outputs 1–6
These six electronically balanced XLR outputs correspond to the low, mid, and high output processing chains. Note that
crossover frequencies can be extended to overlap each other in the crossover processing module, allowing for more
flexible crossover configuration, such as configuring multiple outputs for full range operation.
5. Inputs 1–2
Connect your mixer outputs to these electronically balanced XLR input connectors. These inputs can be configured for
stereo or mono applications in the Wizard. The input sensitivity of these jacks are affected by the +4dBu/-10dBV switch.