® DriveRack /ZonePRO ® ™ ZC Series Wall-Mounted Zone Controllers ZC Series ZC-1-4 ZC-6-9 ZC-Fire ZC-BOB User Guide
ZC-Remote Control Wall Controllers USER GUIDE DECLARATION OF CONFORMITY Manufacturer’s Name: Manufacturer’s Address: dbx Professional Products 8760 S. Sandy Parkway Sandy, Utah 84070, USA declares that the product: Product name: dbx Zone Controllers Models: ZC1, 2, 3, 4, 6, 7, 8, 9, FIRE and BOB Product name may be suffixed by the letters -EU.
ZC-Remote Control Wall Controllers USER GUIDE Zone Controller Wiring The Zone Controllers, (ZC-1, ZC-2, ZC-3, ZC-4, ZC-6, ZC-7, ZC-8, ZC-9, and ZC-Fire) can be wired serially or in parallel. To wire in series each Zone Controller must have an identification or zone number chosen using the DIP switches on the side of the controller (see diagram A).
ZC-Remote Control Wall Controllers USER GUIDE Diagram C Diagram D ZC-4 ZC-4 Binary App notes SW4 SW3 SW2 SW1 Hex Setting 0 0 0 0 0 0 0 0 0 1 1 1 0 0 1 0 2 2 0 0 1 1 3 3 0 1 0 0 4 4 0 1 0 1 5 5 0 1 1 0 6 6 0 1 1 1 7 7 1 0 0 0 8 8 1 0 0 1 9 9 1 0 1 0 A 10 1 0 1 1 B 11 1 1 0 0 C 12 1 1 0 1 D 13 1 1 1 0 E 14 1 1 1 1 F 15 Switches SW1-SW4 correspond to switch inputs 1-4 on the ZC4's EuroBlock connector.Each switch connected to the ZC4 must be a Dual Pole Single Throw (DPST).
ZC-Remote Control Wall Controllers USER GUIDE Connect a 5-24V DC control voltage to this connector. RELAY/ SWITCH CLOSURE INPUTS CONTROL VOLTAGE 5-24 VDC OUT IN RJ45 - CONNEC T ONLYTO ZONE CONTROLLERINPUT Diagram E Or Connect a normally open or normally closed relay closure to this connector. ZC-Fire Zone Controller Maximum Cable Length Note - The following cable lengths were achieved using Cat5 Enhanced cable exhibiting a maximum D.C. resistance of 29 Ohms per 1,000 feet.
ZC-Remote Control Wall Controllers USER GUIDE Diagram F Diagram G Diagram H ® 6 DriveRack®/ZonePRO™ User Manual
USER GUIDE ZC-Remote Control Wall Controllers Cable Spec: Cat5 Cable - 4-Twisted Pairs of 24AWG wire RJ-45 (8-Position) White/Orange Orange White/Green Green White/Blue Blue White/Brown Brown 1 2 3 4 5 6 7 8 RJ-45 (8-Position) 1 -VREF 2 -Zone 1 3 -Zone 2 4 -Zone 3 5 -Zone 4 6 -Zone 5 7 -Zone 6 8 -GND Zone Controller Compatibility Chart ZC DriveRack 260 ZonePro 640/641 ZonePro 1260/1261 1 DriveRack 220i x x x x 2 x x x x 3 x x x x 4 x x x x FIRE x x 6 x x 7 x x 8 x x
USER GUIDE ZC-Remote Control Wall Controllers Safety Warning: The installation of the Zone Controllers MUST be accomplished with the use of cable which is rated VW-1 or higher. Common NEC designations which meet this rating include: CMP, CMR, CMG, CM and CMX.