Installation Guide 30" All Grill, LP Gas

4
CUTOUT DIMENSIONS
Notes:
zz
When determining a suitable location, take into account concerns such as exposure to
wind, proximity to traffic paths, and keeping any gas supply lines as short as possible.
zz
Locate the unit in a well-ventilated area.
zz
The counter and supporting ledges or deck must be level and flat.
zz
The enclosure should have ventilation holes to prevent gas build-up in the event of a
leak. Refer to ANSI Z21.58 Standard for Outdoor Cooking Gas Appliances, Section 1.7
Enclosures For Self Contained LP-Gas Supply Systems.
Notes:
zz
Use only the DCS insulated jacket which has specifically been designed and tested for
this purpose.
zz
To purchase access doors and drawers, visit dcsappliances.com
zz
30” access doors model number: ADN1-30
zz
30” access drawers model number: ADR2-30
CUTOUT DIMENSIONS
BE1-30 MODELS
INCHES MM
A Height of cutout 10 1/8 257
B Depth of cutout 22 3/4 578
C Width of cutout 28 1/2 724
D Depth of gas supply opening 4 15/16 125
E Width of gas supply opening 4 102
CUTOUT DIMENSIONS
BE1-30 MODELS
INCHES MM
A Height of cutout 11 1/8 283
B Depth of cutout 23 3/4 603
C Width of cutout 34 7/8 886
D Depth of gas supply opening 4 102
E Width of gas supply opening 4 102
F Depth to gas supply opening from front of cutout 18 1/2 470
G Width to gas supply opening from side of cutout 3 1/2 89
STANDARD CUTOUT INSULATED JACKET CUTOUT
a
b
c
d
e
a
b
c
e
d
g
f
If the unit is to be placed into a combustible enclosure, an insulated jacket is required.
ventilationventilation